61 13 ... Crimping Micro Quadlock System contacts (MQS): Procedure

WARNING: This page is about a different car, the 2003 BMW X5 and 2002 BMW X5. However, it is still accessible from the selected car via links, so may be relevant.

To crimp MQS contacts, use pliers 61 4 321 (1) in conjunction with crimping head 61 4 324 (2) from crimping set 61 4 320.

NOTE: Pliers (1) open automatically as far as they will go when handles are pressed together.
Fig 1: Identifying Crimping Set Pliers 61 4 321 & Crimping Head 61 4 325
G03256483Courtesy of BMW OF NORTH AMERICA, INC.

Open pliers (1).

Fold up contact carrier (2).

Insert MQS contact (3) in contact carrier (2).

Fold back contact carrier (2).

Fig 2: Inserting MQS Contact In Contact Carrier
G03256484Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Follow procedure for cutting and stripping insulation from cables.

Close pliers (1) one notch.

Insert stripped cable (2).

Fig 3: Inserting Stripped Cable
G03256485Courtesy of BMW OF NORTH AMERICA, INC.

Close pliers (1) fully.

Open pliers (1).

Open contact carrier (2) gently and carefully remove MQS contact.

NOTE: Check contact for correct crimping.
Fig 4: Removing MQS Contact Carrier
G03256486Courtesy of BMW OF NORTH AMERICA, INC.