12 14 522 Replacing pulse generator on left inlet camshaft (M62)
WARNING: This page is about a different car, the 2003 BMW X5 and 2002 BMW X5. However, it is still accessible from the selected car via links, so may be relevant.
Interrogate fault memory of DME control unit.
Switch off ignition.
Turn fasteners on acoustic cover 90° counterclockwise.
Remove acoustic cover.
Disconnect plug connection (1) on left cable strip. Unclip cable from cable holder (2).
Release screw (3).
Remove pulse generator (4).
Installation:
Coat sealing ring with anti-friction rubber coating (e.g. petroleum jelly).
NOTE:
Interrogate fault memory of DME control unit.
Check stored fault messages.
Rectify faults.
Now clear the fault memory.
Check stored fault messages.
Rectify faults.
Now clear the fault memory.