16 00 005 Draining and filling fuel tank
Special tools required:
Ensure adequate ventilation in the place of work!
Connect the exhaust and extraction systems to the exhaust tailpipe.
The electric fuel pump must not operate without fuel! After completing repairs but before starting the engine for the first time, fill the fuel tank with min. 5 l fuel through the fuel filler pipe.
Do not damage non-return flap when pulling out extraction hose.
Diesel vehicles
Before starting the engine for the first time, if the tank has been run dry or drawn off, fill with diesel fuel and turn on ignition for approx. 1 minute. The fuel circuit is thus filled and vented, which results in the engine firing more quickly.
Drawing off fuel
Start engine and allow to run.
The electric fuel pump runs.
In this way, the fuel is repumped through the suction jet pump from the left to the right side of the fuel tank.
Insert special tool 16 1 080 into fuel filler neck.
Special tool 16 1 080 has two different diameters for petrol/gasoline and diesel vehicles!
Slide extraction hose of extractor unit through special tool 16 1 080 into the fuel filler pipe, turning in the process if necessary.
Insertion length approx. 170 cm.
Draw off fuel with suction unit as far as possible.
Follow drawing off of fuel on fuel gauge in instrument cluster.
Drawing off residual fuel quantity
Drawing off residual fuel amount is not included in the time value of this operation.
Catch dripping fuel in a suitable container.
Remove flange cover . See 16 14 200 REMOVING AND INSTALLING/REPLACING FLANGE COVER (OUTER FUEL FILTER) or 16 14 200 REMOVING AND INSTALLING/REPLACING FLANGE COVER .
Draw off residual fuel quantity through service openings.
Fuel filling
Insert special tool 16 1 080 into fuel filler neck.
Special tool 16 1 080 has two different diameters for petrol/gasoline and diesel vehicles!
Slide extraction hose of extractor unit approx. 40 cm into fuel filler pipe.
Fill fuel from suction extractor unit.
Extracting fuel after a defect in the suction jet pump or fuel pump
Draw off right half of tank completely through fuel filler pipe.
Remove flange cover . See 16 14 200 REMOVING AND INSTALLING/REPLACING FLANGE COVER (OUTER FUEL FILTER) or 16 14 200 REMOVING AND INSTALLING/REPLACING FLANGE COVER .
Insert extraction hose through service opening in tank, fuel (also residual quantity) can be drawn off.