64 50... Leak detection with ultraviolet additives (UV additives) (BMW leak-testing case): Notes
WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2012 BMW 328xi, 2012 BMW 328i, 2011 BMW 328xi, 2011 BMW 328i, and 2010 BMW 328xi. However, it is still accessible from the selected car via links, so may be relevant.
IMPORTANT:
UV leak detection is prohibited in EU countries.
In all other countries, follow the country-specific regulations.
In all other countries, follow the country-specific regulations.
IMPORTANT:
It is absolutely essential to read and comply with the equipment manufacturer's operating instructions use provided in the equipment case!
Read and comply with the instructions for use provided with the special tool particularly with regard to accident prevention, health protection and environmental protection.
Use only BMW-approved UV additives (e.g. TRACER).
Only the basic procedure is described in the following!
Read and comply with the instructions for use provided with the special tool particularly with regard to accident prevention, health protection and environmental protection.
Use only BMW-approved UV additives (e.g. TRACER).
Only the basic procedure is described in the following!
WARNING:
Avoid contact with refrigerant.
FOLLOW SAFETY PRECAUTIONS WHEN HANDLING REFRIGERANT .
FOLLOW SAFETY PRECAUTIONS WHEN HANDLING REFRIGERANT .
IMPORTANT:
Ultraviolet lamp gets very hot in the radiation area!
Do not use the ultraviolet lamp without the filter glass.
Eyes and skin will suffer damage if the ultraviolet lamp is used without the filter glass.
When using the UV lamp, wear the safety goggles provided in the case.
Do not use the ultraviolet lamp without the filter glass.
Eyes and skin will suffer damage if the ultraviolet lamp is used without the filter glass.
When using the UV lamp, wear the safety goggles provided in the case.
NOTE:
- Fill the hose system of the hand pump completely with UV additive PRIOR to use
- Use the UV additive exclusively for BMW-approved refrigerant fluids
- Do not operate the air conditioning system while the hand pump is connected or in use
- The air conditioning system must always be filled with an adequate amount of refrigerant to enable the leak-detecting agent to be properly distributed