72 12 060 Removing and installing/replacing left or right head airbag
Incorrect handling can activate airbag and cause injury.
Necessary preliminary tasks
- Disconnect BATTERY NEGATIVE LEAD
- Follow INSTRUCTIONS for unlocking and locking airbag plug connections
- Remove ROOFLINER
Head airbag installation summary:
Release screw (1) on end fitting.
Tightening torque 72 12 05AZ .
Release screw (2) on folding pack holder.
Tightening torques 72 12 04AZ .
Folding pack holder (3) is screwed to trim for roof pillar at front.
Installation:
If screws (1...3) slip, coat them with Loctite.
If necessary, lever out clip-mounted holder.
If necessary, slide wiring harness (2) to one side to release screw (1) on folding pack holder.
Tightening torque 72 12 04AZ .
Release screw (3) from folding pack holders.
Tightening torques 72 12 04AZ .
Installation:
If screws (1) and (3) slip, coat them with Loctite.
If necessary, lever out clip-mounted holder.
Unlock PLUG CONNECTION (4) and disconnect.
Release screws (1) on B-pillar ramp.
Tightening torque 72 1206AZ .
Unscrew bolt (3).
Tightening torque 72 12 03AZ .
Remove gas generator (5) with head airbag.