6520030 Removing and installing/replacing empty housing for roof-mounted serial: Installation
The cover of the multiband telephone aerial is secured with window adhesive. All preparatory operations correspond to the WINDOW CEMENTING INSTRUCTIONS .
Bonding surface (2) must be clean and free from grease.
Position two spacers (1) on cleaned aerial cover.
Dimensions:
- 10 mm
- 14 mm
Position spacer (2) centrally and flush with shoulder of adhesive flange.
Apply trace of adhesive bead all round outer contour as follows.
Distance between adhesive bead and edge of aerial cover:
- 6.5 mm ± 1 mm
Start and end of bead trace must have an overlap length of max. 10 mm.
If necessary, secure aerial cover with adhesive tape and do not press down on one side of the aerial more firmly than the other.
After bonding, leave vehicle to stand for at least 3 hours at room temperature.
To guarantee a permanent bond:
Only use washing installations after a period of 24 hours has passed.