6762020 Removing and installing/replacing flat motor for rear left or right power window unit
WARNING: This page does not describe the selected car, but rather 10 other vehicles, including the 2011 BMW 328xi, 2011 BMW 328i, 2010 BMW 335xi, 2010 BMW 335i, and 2010 BMW 328xi. However, it is still accessible from the selected car via links, so may be relevant.
Necessary preliminary tasks:
- Remove rear POWER WINDOW UNIT
Release screws (1), tightening torque 51 35 1AZ .
Detach flat motor for power window unit (2) in direction of arrow from power window unit (3).
Installation:
Fit flat motor for power window unit (2) exactly on teeth of power window unit.
Replacement:
A normalization must be carried out in order to activate anti-trapping protection.
Operating sequence for normalization:
- Operate corresponding power window switch in "Close" setting.
- Once the upper end position has been reached, hold power window switch down for approx. 1 second more.
If necessary, repeat procedure again.
Normalization is thus completed.
NOTE:
Carry out function check (one-touch function, anti-trapping protection and, if necessary, comfort function).