LEMON Manuals: Even more car manuals for everyone
Home >> Mini >> 2010 >> Cooper S, 2D Hatchback, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 2692 (General Electrical System - Repair - E90) >> 6113 Plug Connection, Terminal, Fuse Box >> 6113... Installing comb connector for retrofitting/repairs >> Installation in wet area (engine compartment, wheel arch)

Installation in wet area (engine compartment, wheel arch)

WARNING: This page does not describe the selected car, but rather 14 other vehicles, including the 2011 BMW 328xi, 2011 BMW 328i, 2011 BMW 323i, 2010 BMW 335xi, and 2010 BMW 335i. However, it is still accessible from the selected car via links, so may be relevant.

Apply sealing compound on both sides and press into contacts (1).

Fit shrink-fit hose and heat up with hot air blower (2) (approx. 250°C).

NOTE: Ensure that fan connector has sufficient contact surface on mounting point.
Do not heat shrink-fit hose on edges of fan connector too strongly, risk of cracking.

Allow shrink-fit hose to cool down until hand-warm. Then press sealing material again into contacts and onto edges of fan connector.

If necessary, carefully heat shrink-fit hose again.

Fig 1: Identifying Shrink-Fit Hose With Contacts
G04727493Courtesy of BMW OF NORTH AMERICA, INC.