LEMON Manuals: Even more car manuals for everyone
Home >> Mini >> 2010 >> Cooper S, 2D Hatchback, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 246 (General Electrical System - Repair Instructions - X5 (4.4L)) >> Plug Connections Terminals >> 61 13 ... Crimping Micro QUADLOCK System Contacts (MQS)

61 13 ... Crimping Micro QUADLOCK System Contacts (MQS)

WARNING: This page is about a different car, the 2003 BMW X5, 2002 BMW X5, 2001 BMW X5, and 2000 BMW X5. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

To crimp MQS contacts, use pliers 61 4 321 (1) in conjunction with crimping head 61 4 324 (2) from crimping set 61 4 320.

NOTE: Pliers (1) open automatically as far as they will go when handles are pressed together.
Fig 1: Using Pliers In Conjunction With Crimping Head From Crimping Set
G03253554Courtesy of BMW OF NORTH AMERICA, INC.

Open pliers (1).

Fig 2: Inserting MQS Contact In Contact Carrier
G03253555Courtesy of BMW OF NORTH AMERICA, INC.

Fold up contact carrier (2).

Insert MQS contact (3) in contact carrier (2).

Fold back contact carrier (2).

NOTE: Follow procedure for cutting and stripping insulation from cables.

Close pliers (1) one notch.

Insert stripped cable (2).

Close pliers (1) fully.

Fig 3: Inserting Stripped Cable
G03253556Courtesy of BMW OF NORTH AMERICA, INC.

Open pliers (1).

Fig 4: Removing MQS Contact
G03253557Courtesy of BMW OF NORTH AMERICA, INC.

Open contact carrier (2) gently and carefully remove MQS contact.

NOTE: Check contact for correct crimping.