Home >> Mini >> 2010 >> Cooper S, 2D Hatchback, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 2241 (General Electrical System - Repair - E92/93) >> Plug Connection, Terminals >> 61 13... Opening plug housings and removing contacts of different plug systems >> 61 13... Socket housing 42-, 43-pin, Hybrid System MQS / MPQ

61 13... Socket housing 42-, 43-pin, Hybrid System MQS / MPQ

WARNING: This page is about a different car, the 2010 BMW M3, 2009 BMW M3, and 2008 BMW M3. However, it is still accessible from the selected car via links, so may be relevant.

Manufactured by AMP:  The following contact types without strand sealing can be fitted in the socket housings:

Open secondary locks (1) on socket housing.

Press back retaining hook of MQS contacts (2) with special tool 61 1 134 and pull out cable with contact.

Press back retaining hook of MPQ contacts (3) with screwdriver or similar tool and pull out cable with contact.

Fig 1: Pressing Back Retaining Hook Of MPQ Contacts
G05478537Courtesy of BMW OF NORTH AMERICA, INC.

Installation: 

Bend open retaining hook of contacts gently before inserting into plug housing.

To install contacts, observe cavity numbers on reverse side of socket housing.

Fig 2: Identifying Plug Housing
G05478538Courtesy of BMW OF NORTH AMERICA, INC.