11 51 000 Removing and installing/replacing water pump (N52K)
Only perform this work after engine has cooled down.
Recycling:
Catch and dispose of drained coolant in a suitable container.
Observe country-specific waste-disposal regulations.
Mixture ratio, water : coolant = 1 : 1
Protect plug connections against coolant and contamination.
Cover plug connections with suitable materials.
No steel screws/bolts may be used due to the threat of electrochemical corrosion.
A magnesium crankcase requires aluminum screws/bolts exclusively.
Aluminum screws/bolts must be replaced each time they are released.
The end faces of aluminum screws/bolts are painted blue for the purposes of reliable identification
Jointing torque and angle of rotation must be observed without fail (risk of damage) .
Necessary preliminary tasks:
- Remove coolant thermostat. See 11 53 000 Removing and installing/replacing coolant thermostat (N52K)
Unfasten hose clip (1).
For tightening torque refer to 11 53 5AZ in 11 53 COOLANT THERMOSTAT WITH CONNECTIONS .
Remove coolant hose.
Unfasten hose clip (2).
For tightening torque refer to 11 53 3AZ in 11 53 COOLANT THERMOSTAT WITH CONNECTIONS .
Remove coolant hose.
Disconnect plug connection (3).
Release screws (4).
For tightening torque refer to 11 51 1AZ in 11 51 ELECTRIC WATER PUMP WITH DRIVE .
Installation:
Replace aluminum screws.
Remove electric water pump (x) via x.
Installation:
If the electric water pump is reused, it must be rotated one turn due to the breakaway torque at the blade wheels.
Assemble engine.
Venting instructions must be observed without fail. . See 17 00 005 DRAINING AND ADDING COOLANT (N52K) .