24 14 001 Replacing Selector Shaft Seal (GA6HP26Z/6HP32Z)
Special tools required:
- 24 5 361
- 24 5 362
- 24 5 364
- 24 5 366
After completion of work, check transmission fluid level. See 00 11 500 CHECKING/TOPPING UP FLUID LEVEL IN AUTOMATIC TRANSMISSION (GA6HP26Z/6HP32Z)
Use only the approved transmission fluid. See AUTOMATIC TRANSMISSION - OPERATING FLUIDS .
Failure to comply with this requirement will result in serious damage to the automatic transmission!
Necessary preliminary tasks:
Remove underbody protection.
E65/M67TU only
Release screws.
Remove transmission underguard (1).
Remove left diesel particulate filter.
E65/N62 only:
Release screws.
Remove transmission underguard (1).
Remove left oxygen sensor. See 11 78 540 REPLACING LEFT LAMBDA OXYGEN MONITOR SENSOR (N73)
E60/E63/ E64, N62 only:
Remove rear underbody protection.
Remove left oxygen sensor (N62 only).
Unfasten nut.
Remove cable (1).
Installation:
Adjusting cable:
- Release nut
- Adjust cable by means of holder (2)
Distance A ≥ 1 mm.
Grip clamping sleeve (1) and slacken nut (2).
Tightening torque 25 16 2AZ. See 25 16 SHIFT CONSOLE - AUTOMATIC TRANSMISSION
Detach retainer (3) towards bottom using a screwdriver.
Pull cable (4) out of holder.
Installation:
Adjust selector lever. See 24 00 018 ADJUSTING SELECTOR LEVER (A5S 360R/390R, A4S 200R, 6HP26Z/19Z)
Release shift cable head (2) from ball head.
Installation:
Adjust selector lever.
Illustration similar.
Unfasten nut.
Take off holder (1).
Tightening torque 24 51 1AZ. See 24 51 EXTERNAL SHIFT LINKAGE
Screw in special tool 24 5 361 until it is firmly connected with shaft seal.
Screw special tool 24 5 362 onto special tool 24 5 361 and tighten down.
This pulls the shaft seal out of the transmission housing.
Oil sealing lip on shaft seal (1).
Screw in shaft seal (1) with special tools 24 5 366 and 24 5 364 as far as it will go.