11 78 613 Replacing both oxygen monitor sensors (M52TU / M54 / M56)
Special tools required:
- 11 7 020
- 11 7 030
- (for work step number 13 00 002)
- Read out fault memory, clear if necessary.
Illustrations show M54.
E46 only
Remove microfilter.
Open cable duct on lower section of microfilter housing (2) and feed out cable (s).
Release screws (1) and remove lower section of microfilter housing (2).
Remove cover from fuel injectors.
Mark plug connections.
Unclip the cable from the retainer.
Disconnect plug. Unclip cable on rear side of engine from cable guide.
In event of unfavorable tolerances, accessibility to the oxygen monitor sensor from cylinders 4 to 6 is only possible after the exhaust system has been removed.
Release oxygen monitor sensor from cylinders 1 to 3 with special tool 11 7 030.
Release oxygen monitor sensor from cylinders 4 to 6 with special tool 11 7 020.
Installation:
The threads of new oxygen monitor sensors are already coated with Never Seez compound.
If an oxygen monitor sensor is reused, only apply a thin and uniform coat of Never Seez compound to thread.
Part of oxygen control sensor which projects into exhaust system branch must not be cleaned or come into contact with lubricant.
Installation:
Secure oxygen monitor sensor for cylinders 1 to 3 with special tool 11 7 030.
Secure oxygen monitor sensor for cylinders 4 to 6 with special tool 11 7 020.
Tightening torque, refer to 11 78 1AZ in ENGINE - TIGHTENING TORQUES .
Cover oxygen monitor sensors when applying underseal.
Pay attention to cable routing of oxygen monitor sensors.