12 14 521 Replacing pulse generator on crankshaft
Necessary preliminary tasks:
- Switch off ignition
- Read out fault memory of DME control unit
NOTE:
For purposes of clarity, the following work step is shown on the engine after it has been removed.
Remove cover (1).
Unlock plug (1) and remove.
Release screw and remove pulse generator.
Tightening torque: 5Nm
NOTE:
Check stored fault messages.
Now clear the fault memory.
Now clear the fault memory.