Home >> Mini >> 2008 >> Cooper S, 2D Convertible, Automatic >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating And Air Conditioning - Repair - Cooper (R50) , Cooper S (R53) & Convertible (R52) >> Air Conditioning System >> 64 50 009 Drawing off, evacuating and filling A/C system (R 134a)

64 50 009 Drawing off, evacuating and filling A/C system (R 134a)

WARNING: Avoid contact with refrigerant and refrigerant oil. Follow safety instructions for handling refrigerant R 134a. Refer to 64 50 ... SAFETY INSTRUCTIONS FOR HANDLING REFRIGERANT R 134A . Follow safety instructions for handling refrigerant oil. Refer to 64 50 ... SAFETY PRECAUTIONS WHEN HANDLING REFRIGERANT OIL (FOR REFRIGERANT R 134A) .
IMPORTANT: Risk of damage! Restart engine only when A/C system has been correctly filled.
NOTE:

Draw off, evacuate and fill the A/C system in accordance with the operating instructions of the relevant service station.

Instructions For Drawing Off A/C System: 

To help separation of refrigerant and refrigerant oil, run engine at low speed (800-1200 rpm) and with A/C system turned on for a few minutes.

The limits the entrainment of refrigerant oil while it is drawn off.

Drawn-off refrigerant oil must be changed and reintroduced via the service station.

If at the end of the drawing-off procedure the service station moisture indicator shows that the drawn-off refrigerant is excessively moist, clean the refrigerant in accordance with the service station operating instructions.

Recycling:

Dispose of drawn-off refrigerant oil as hazardous waste.

Observe country-specific waste-disposal regulations.

Instructions For Evacuating Off A/C System: 

The evacuation procedure removes all traces of ambient air, water vapor and any other gases present from the A/C system.

This enables subsequent system filling with refrigerant.

A decrease in the vacuum level indicates a leak in the refrigerant circuit. Refer to 64 50 ... LEAK-TESTING WITH LEAK TESTER DEVICE .

Instructions For Filling A/C System: 

Before filling with refrigerant, top up the refrigerant oil entrained during drawing off.

Depending on the type of component replaced on the A/C system, it may be necessary to top up the refrigerant oil, even if no measurable losses have occurred during drawing off.

Read and comply with the A/C system manufacturer's notes in this regard and the operating instructions of the relevant service station.

Information on the required refrigerant fill quantity for the entire A/C system is contained on the rating plate (1) in the engine compartment.

If necessary, refer to HEATING AND AIR CONDITIONING - TECHNICAL DATA - COOPER (1.6L) R50/W10 for fill quantities.

Installation: 

Reseal refrigerant filler necks on vehicle with sealing caps.