Side Play
- Mount Dial Indicator (4201-C) with Plunger (T79L-4201A) extended through oil outlet tube to contact shaft.
- Apply pressure to adjust turbine assembly away from dial indicator.With turbine assembly fully adjusted in the opposite direction, zero the dial indicator.
- Pull the turbine assembly toward indicator and measure the clearance. If side play is less than .003" (.075 mm) or exceeds .006" (.150 mm), turbocharger assembly should be replaced.