End Play
- With turbocharger removed, attach Dial Indicator (4201-C) to the center housing so that the plunger contacts the shaft. See Fig 1 . Push turbine assembly away from gauge and set dial indicator to zero.
- Push turbine assembly into dial indicator to measure clearance. If bearing clearance is below .001" (.025 mm) or exceeds .003" (.075 mm) replace the turbocharger assembly.