Normal Operation
Under normal operation, when A/C is requested the HVAC module then sends an A/C request message over the Medium Speed Controller Area Network (MS-CAN) bus to the Instrument Cluster (IC), then from the IC through the High Speed Controller Area Network (HS-CAN) bus to the PCM.
Voltage is provided to the A/C clutch relay switch contacts. When the PCM energizes the relay, voltage is supplied to the A/C compressor clutch field coil. The A/C compressor clutch field coil is grounded.
The evaporator discharge air temperature sensor is used for A/C compressor cycling. An accurate evaporator discharge air temperature is critical for compressor engagement. The temperature measurement is used by the PCM to turn off the A/C compressor when the evaporator temperatures are cold enough to freeze the condensation.
When an A/C request is received by the PCM, the A/C compressor clutch will only be engaged through the A/C clutch relay if all of the following conditions are met:
- The A/C pressure transducer does not indicate excessively low or high refrigerant pressure. Refer to SPECIFICATIONS .
- The PCM does not detect excessively high engine coolant temperature.
- The PCM does not detect an ambient air temperature below 0°C (32°F).
- The PCM has not detected a Wide Open Throttle (WOT) condition.
- The HVAC module does not detect an evaporator discharge air temperature below 0°C (32°F).
This pinpoint test is intended to diagnose the following:
- Fuse(s)
- Wiring, terminals or connectors
- Evaporator discharge temperature sensor
- A/C pressure transducer
- PCM
- HVAC module
- A/C compressor clutch field coil
- A/C clutch relay
- A/C clutch air gap
- Battery Junction Box (BJB)