Pinpoint Test D: DTC B1255 Or B1257
WARNING: This page is about a different car, the 2010 Mercury Mariner and 2010 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
- D1 CHECK THE SENSOR RESISTANCE
- Ignition OFF.
- Disconnect: Ambient Temperature Sensor C132.
- Measure the resistance between the ambient temperature sensor C132 terminals.
- Is the resistance within the specified values for these temperature ranges: 10-20°C (50-68°F), 37,000-58,000 ohms; 20-30°C (68-86°F), 24,000-37,000 ohms; 30-40°C (86-104°F), 16,000-24,000 ohms?
- Yes: GO to D2 .
- No: INSTALL a new ambient temperature sensor. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- D2 CHECK THE SENSOR OUTPUT VOLTAGE
- Ignition ON.
- Press the AUTO button.
- Measure the voltage between ambient temperature sensor C132-1, circuit VH407 (YE/GN), harness side and C132-2, circuit RH111 (GY/BU), harness side.
- Is the voltage between 4.7 and 5.1 volts?
- D3 CHECK CIRCUIT VH407 (YE/GN) FOR AN OPEN
- Ignition OFF.
- Disconnect: HVAC Module - DATC C2356A.
- Measure the resistance between HVAC module - DATC C2356A-2, circuit VH407 (YE/GN), harness side and ambient temperature sensor C132-1, circuit VH407 (YE/GN), harness side.
- Is the resistance less than 5 ohms?
- Yes: GO to D4 .
- No: REPAIR circuit VH407 (YE/GN) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- D4 CHECK CIRCUIT RH111 (GY/BU) FOR AN OPEN
- Measure the resistance between HVAC module - DATC C2356A-10, circuit RH111 (GY/BU), harness side and ambient temperature sensor C132-2, circuit RH111 (GY/BU), harness side.
- Is the resistance less than 5 ohms?
- Yes: GO to D7.
- No: REPAIR circuit RH111 (GY/BU) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- D5 CHECK CIRCUIT VH407 (YE/GN) FOR A SHORT TO CIRCUIT RH111 (GY/BU)
- Ignition OFF.
- Disconnect: HVAC Module - DATC C2356A.
- Measure the resistance between ambient temperature sensor C132-1, circuit VH407 (YE/GN), harness side and C132-2, circuit RH111 (GY/BU), harness side.
- Is the resistance greater than 10,000 ohms?
- Yes: GO to D6 .
- No: REPAIR circuit VH407 (YE/GN) for a short to circuit RH111 (GY/BU). CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- D6 CHECK CIRCUIT VH407 (YE/GN) FOR A SHORT TO GROUND
- Measure the resistance between HVAC module - DATC C2356A-2, circuit VH407 (YE/GN), harness side and ground.
- Is the resistance greater than 10,000 ohms?
- Yes: GO to D7 .
- No: REPAIR circuit VH407 (YE/GN) for a short to ground. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- D7 CHECK THE HVAC MODULE CONNECTION
- Inspect the HVAC module connectors for:
- corrosion.
- pushed-out terminals.
- damaged terminals.
- Connect and correctly seat all the HVAC module connectors.
- Clear the DTCs.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes: INSTALL a new HVAC module. REFER to CLIMATE CONTROL . TEST the system for normal operation.
- No: The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- Inspect the HVAC module connectors for: