Home >> Mercury >> 2010 >> Milan Base, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1199 (HVAC - Climate Control System - General Information And Diagnostics - (Except Hybrid)) >> Diagnosis And Testing >> Climate Control System >> Pinpoint Tests >> Pinpoint Test D: DTC B1255 or B1257 >> Pinpoint Test D: DTC B1255 Or B1257

Pinpoint Test D: DTC B1255 Or B1257

WARNING: This page is about a different car, the 2010 Mercury Mariner and 2010 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
  1. D1 CHECK THE SENSOR RESISTANCE 
    • Ignition OFF.
    • Disconnect: Ambient Temperature Sensor C132.
    • Measure the resistance between the ambient temperature sensor C132 terminals.
      Fig 1: Measuring Resistance Between Ambient Temperature Sensor C132 Terminals
      G06064533Courtesy of FORD MOTOR CO.
    • Is the resistance within the specified values for these temperature ranges: 10-20°C (50-68°F), 37,000-58,000 ohms; 20-30°C (68-86°F), 24,000-37,000 ohms; 30-40°C (86-104°F), 16,000-24,000 ohms? 
    • Yes:  GO to D2  .
    • No:  INSTALL a new ambient temperature sensor. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  2. D2 CHECK THE SENSOR OUTPUT VOLTAGE 
    • Ignition ON.
    • Press the AUTO button.
    • Measure the voltage between ambient temperature sensor C132-1, circuit VH407 (YE/GN), harness side and C132-2, circuit RH111 (GY/BU), harness side.
      Fig 2: Measuring Voltage Between Ambient Temperature Sensor C132-1 And C132-2
      G06098552Courtesy of FORD MOTOR CO.
    • Is the voltage between 4.7 and 5.1 volts? 
    • Yes:  INSTALL a new ambient temperature sensor. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation. If the condition returns, GO to  D7.
    • No : For DTC B1255  , GO to D3  .

      For DTC B1257  , GO to  D5.

  3. D3 CHECK CIRCUIT VH407 (YE/GN) FOR AN OPEN 
    • Ignition OFF.
    • Disconnect: HVAC Module - DATC  C2356A.
    • Measure the resistance between HVAC module - DATC  C2356A-2, circuit VH407 (YE/GN), harness side and ambient temperature sensor C132-1, circuit VH407 (YE/GN), harness side.
      Fig 3: Measuring Resistance Between HVAC Module C2356A-2 And Ambient Temperature Sensor C132-1
      G06064536Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    • Yes:  GO to D4  .
    • No:  REPAIR circuit VH407 (YE/GN) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  4. D4 CHECK CIRCUIT RH111 (GY/BU) FOR AN OPEN 
    • Measure the resistance between HVAC module - DATC  C2356A-10, circuit RH111 (GY/BU), harness side and ambient temperature sensor C132-2, circuit RH111 (GY/BU), harness side.
      Fig 4: Measuring Resistance Between HVAC Module - DATC C2356A-10 And Ambient Temperature Sensor C132-2
      G06064537Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    • Yes:  GO to  D7.
    • No:  REPAIR circuit RH111 (GY/BU) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  5. D5 CHECK CIRCUIT VH407 (YE/GN) FOR A SHORT TO CIRCUIT RH111 (GY/BU) 
    • Ignition OFF.
    • Disconnect: HVAC Module - DATC  C2356A.
    • Measure the resistance between ambient temperature sensor C132-1, circuit VH407 (YE/GN), harness side and C132-2, circuit RH111 (GY/BU), harness side.
      Fig 5: Measuring Resistance Between Ambient Temperature Sensor C132-1 And C132-2
      G06098555Courtesy of FORD MOTOR CO.
    • Is the resistance greater than 10,000 ohms? 
    • Yes:  GO to D6  .
    • No:  REPAIR circuit VH407 (YE/GN) for a short to circuit RH111 (GY/BU). CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  6. D6 CHECK CIRCUIT VH407 (YE/GN) FOR A SHORT TO GROUND 
    • Measure the resistance between HVAC module - DATC  C2356A-2, circuit VH407 (YE/GN), harness side and ground.
      Fig 6: Measuring Resistance Between HVAC Module C2356A-2, Circuit VH407 (YE/GN) Harness Side And Ground
      G06064539Courtesy of FORD MOTOR CO.
    • Is the resistance greater than 10,000 ohms? 
    • Yes:  GO to D7  .
    • No:  REPAIR circuit VH407 (YE/GN) for a short to ground. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  7. D7 CHECK THE HVAC MODULE CONNECTION 
    • Inspect the HVAC module connectors for:
      • corrosion.
      • pushed-out terminals.
      • damaged terminals.
    • Connect and correctly seat all the HVAC module connectors.
    • Clear the DTCs.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes:  INSTALL a new HVAC module. REFER to CLIMATE CONTROL . TEST the system for normal operation.