Pinpoint Test Ac: The Wait To Start Warning Indicator Is Never/Always On
WARNING: This page is about a different car, the 2008 Ford RV Cutaway, 2008 Ford Econoline, 2008 Ford E450 Super Duty, and 2008 Ford Cutaway. However, it is still accessible from the selected car via links, so may be relevant.
- AC1 RETRIEVE THE RECORDED DTCs FROM BOTH THE CONTINUOUS AND ON-DEMAND PCM SELF-TESTS
- Check for recorded PCM DTCs from both the continuous and on-demand self-tests.
- Are any PCM DTCs recorded?
- YES : REFER to the appropriate Engine Performance article.
- NO : Go to AC2.
- AC2 RETRIEVE THE RECORDED DTCs FROM BOTH THE CONTINUOUS AND ON-DEMAND INSTRUMENT CLUSTER (IC) SELF-TESTS
- Check for recorded instrument cluster (IC) DTCs from the continuous and on-demand self-tests.
- Is DTC U0100 recorded?
- YES
: For DTC U0100, go to Pinpoint Test AH .
For all other DTCs, REFER to DTC Charts .
- NO : Go to AC3.
- AC3 CARRY OUT THE INSTRUMENT CLUSTER WARNING LAMPS AND CHIME ACTIVE COMMAND USING THE SCAN TOOL
- Key in ON position.
- Enter the following diagnostic mode on the diagnostic tool: Instrument Cluster (IC) DataLogger
- Select the instrument cluster (IC) all lamps (ALL_LAMP) active command. Command all the indicators on and off. Observe the wait to start indicator.
- Does the wait to start indicator illuminate when commanded on, and turn off when commanded off?
- AC4 CHECK FOR CORRECT PCM OPERATION
- Disconnect all the PCM connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the PCM connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- YES : INSTALL a new PCM. REFER to ELECTRONIC ENGINE CONTROLS - DIESEL ENGINE article. TEST the system for normal operation.
- NO : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
- AC5 CHECK FOR CORRECT INSTRUMENT CLUSTER (IC) OPERATION
- Disconnect all the instrument cluster (IC) connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the instrument cluster (IC) connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- YES : INSTALL a new instrument cluster (IC). REFER to Instrument Cluster (IC) . TEST the system for normal operation.
- NO : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.