Home >> Mercury >> 2009 >> Mariner Base, 2.5 7, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 7 (Engine Controls - Powertrain DTC Charts & Descriptions - (Hybrid)) >> Diagnostic Trouble Code (DTC) Charts and Descriptions >> DTC P1408: Exhaust Gas RECIRCULATION (EGR) Flow Out Of Self-Test Range

DTC P1408: Exhaust Gas RECIRCULATION (EGR) Flow Out Of Self-Test Range

WARNING: This page is about a different variant/trim than selected.
P1408 - EXHAUST GAS RECIRCULATION (EGR) FLOW OUT OF SELF-TEST RANGE

Description:  This test is carried out during the key on engine running (KOER) on-demand self-test only. The EGR system is commanded on at a fixed engine speed. The test does not pass and the DTC is set when the measured EGR flow falls above or below the required calibration.
Possible Causes:  See possible causes for DTC P0400.
Diagnostic Aids:  For EEGR, use the output state control function of the scan tool and monitor the MAP PID (MAP) and the EEGR PID (EGRMDSD) while commanding the EEGR on. If EGR is introduced into the engine at idle, the RPM drops or stalls out.
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All - GO to PINPOINT TEST KD . -