Pinpoint Test H: The Air Conditioning (A/C) Is Always On - A/C Mode Always Commanded On
WARNING: This page is about a different variant/trim than selected.
NOTE:
Before carrying out the following test, diagnose any PCM or Instrument Cluster (IC) DTCs.
- H1 CHECK THE AIR CONDITIONING SWITCH STATUS (CC_AC) HVAC PID WITH THE A/C OFF
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: CC_AC HVAC PID.
- Select PANEL mode on the HVAC module and make sure the A/C button and indicator are OFF.
- Does the CC_AC HVAC PID read OFF?
- Yes: GO to H2 .
- No: GO to H5.
- H2 CHECK THE AIR CONDITIONING REQUEST SIGNAL (AC_REQ) PCM PID WITH THE A/C OFF
- Enter the following diagnostic mode on the scan tool: AC_REQ PCM PID.
- Select PANEL mode on the HVAC module and make sure the A/C button and indicator are OFF.
- Does the AC_REQ PCM PID read OFF?
- Yes: GO to H3 .
- No: GO to H6.
- H3 CHECK THE AIR CONDITIONING CLUTCH ALLOWED (ACCLT_ALW) PCM PID
- Ignition OFF.
- Disconnect: Dual-Function Pressure Switch C1062.
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: ACCLT_ALW PCM PID.
- Press the PANEL and A/C manual override buttons (A/C indicator ON) on the HVAC module.
- Does the ACCLT_ALW PCM PID read YES?
- Yes: REPAIR circuit CH421 (GY) for a short to voltage. TEST the system for normal operation.
- No: GO to H4 .
- H4 CHECK THE A/C COMPRESSOR OPERATION
- Ignition OFF.
- Connect: Dual-Function Pressure Switch C1062.
- Disconnect: Low Charge Protection Switch C130.
- With the engine running, press the PANEL and A/C manual override buttons on the HVAC module.
- Does the A/C compressor operate?
- Yes: GO to H6.
- No: INSTALL a new A/C low charge protection switch. REFER to CLIMATE CONTROL . TEST the system for normal operation.
- H5 CHECK THE MODULE CONNECTION
- Ignition OFF.
- Disconnect all the HVAC module connectors.
- Check for:
- corrosion.
- pushed-out terminals.
- damaged terminals.
- Connect and correctly seat all the HVAC module connectors.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes: INSTALL a new HVAC module. REFER to CLIMATE CONTROL . TEST the system for normal operation.
- No: The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. TEST the system for normal operation.
- H6 CHECK THE PCM MODULE CONNECTION
- Clear the DTCs.
- Disconnect all of the PCM connectors.
- Check for:
- corrosion.
- pushed-out connectors/pins.
- incorrectly seated connector.
- Connect and correctly seat all of the PCM connectors.
- Operate the system.
- Does the concern return?
- Yes: INSTALL a new PCM. TEST the system for normal operation.
- No: The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.