PINPOINT TEST C: THE CHARGING SYSTEM WARNING INDICATOR IS ON WITH THE ENGINE RUNNING AND NO CHARGING SYSTEM DTCs PRESENT
WARNING: This page is about a different car, the 2009 Ford Mustang. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Make sure battery voltage is greater than 12.2 volts prior to carrying out this pinpoint test.
NOTE:
Do not have a battery charger attached during vehicle testing.
- C1 CHECK THE BATTERY CONDITION
- Carry out the Battery - Condition Test to determine if the battery can hold a charge and is OK for use. Refer to BATTERY, MOUNTING AND CABLES .
- Does the battery pass the condition test?
- YES : Go to C2.
- NO : INSTALL a new battery. REFER to BATTERY, MOUNTING AND CABLES . TEST the system for normal operation.
- C2 CHECK THE GENERATOR B+ CONNECTION
- Key in OFF position.
- Inspect generator C102b connection. Connection should be tight.
- Measure the voltage between generator C102b, circuit 2037 (RD) and ground.
- Is generator C102b connection tight and does the generator B+ measure battery voltage?
- YES : Go to C3.
- NO : TIGHTEN the generator B+ connection or REPAIR the circuit. CLEAR the any DTCs. REPEAT the self-test. TEST the system for normal operation.
- C3 CHECK THE VOLTAGE DROP IN THE B+ CIRCUIT 2037 (RD)
- With the engine running, measure the voltage drop between generator B+ C102b, circuit 2037 (RD) and the positive battery terminal.
- Is the voltage drop less than 0.5 volt?
- YES : Go to C4.
- NO : CHECK for any corrosion in the B+ C102b, circuit 2037 (RD), positive battery cable and/or connections. REPAIR as necessary. TEST the system for normal operation.
- C4 CHECK THE DTCs IN THE PCM
- Key in OFF position.
- Connect the diagnostic tool.
- Key in START position.
- Enter the following diagnostic mode on the diagnostic tool: Retrieve PCM DTCs
- Use the recorded PCM DTCs from the continuous and on-demand self tests.
- Are any PCM DTCs recorded?
- YES : For all DTCs EXCEPT charging system DTCs, REFER to the Introduction - Gasoline Engines . If any charging system DTCs are present, go to Pinpoint Test B . If referred here by the PC/ED, go to C5.
- NO : Go to C5.
- C5 MONITOR PID GENFIL
- With the engine running, monitor PID GENFIL.
- Does PID GENFIL show fault?
- YES : Go to C6.
- NO : REPAIR/INSTALL a new IC, IC-to-PCM connection or the PCM. TEST the system for normal operation.
- C6 MONITOR PID VPWR
- With the engine running, monitor PIDS VPWR, GENFIL, GENVDSD.
- Is PID VPWR greater than 15.6 volts?
- C7 CHECK PCM VPWR PID
- With the engine running, measure the battery voltage.
- Monitor the VPWR PID.
- Are the battery voltage and VPWR PID within 0.6 volt of each other?
- C8 MEASURE PCM INPUT VOLTAGE
- Key in OFF position.
- Disconnect: PCM C175b
- Key in ON position.
- Connect a fused (10A) jumper wire between C175b-37 circuit 1769 (BN/PK) and ground.
- Measure the voltage between PCM input voltage pins 35, 36 and 45 to PCM ground pin 10.
- Are voltages within 0.5 volt of PID VPWR?
- YES : INSTALL a new PCM.
- NO : REPAIR high resistance or loose connections between C175b-35 circuit 1118 (RD) 4.0L or circuit 1856 (GY/OG) 5.4L, C175b-36 circuit 1118 (RD) 4.0L or circuit 1856 (GY/OG) 5.4L, C175b-45 circuit 1683 (DG) PCM power circuits or C175b-10, circuit 1205 (BK), PCM ground circuit.
- C9 MONITOR THE PCM PID GENERATOR MONITOR (GENMON) WITH KEY ON/ENGINE RUNNING
- Key in START position.
- With the engine at idle, wait 15 seconds for the GENVDSD PID to increase to greater than 13 volts.
- Monitor PID GENMON at idle and 3,000 RPM.
- Does the GENMON PID read between 3% and 98% at engine idle speed and at 3,000 RPM?
- C10 MONITOR PID GENVDSD
- With the engine running, monitor PID GENVDSD.
- Is PID GENVDSD greater than 15.2 volts?
- YES : REPAIR connection on circuit 35 (OG/LB). INSPECT generator C102a-3 for damage. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation. If no problems are found, INSTALL a new generator. REFER to GENERATOR AND REGULATOR . TEST the system for normal operation.
- NO : REFLASH or INSTALL a new PCM.
- C11 CHECK FOR SHORTED CIRCUITS
- Key in OFF position.
- Disconnect: Generator C102a
- Verify that PID GENMON reads 100%.
- Carry out the Wiggle Test of wiring to determine if PID GENMON changes from 100%.
- Does PID GENMON change from 100%?
- YES : REPAIR short circuit on C102a-1 1817 (YE).
- NO : Go to C12.
- C12 CHECK THE PCM PID GENERATOR MONITOR INPUT TO THE PCM
- Connect a fused (10A) jumper wire between generator C102a-1, circuit 1817 (YE), harness side and ground.
- Key in ON position.
- Monitor the GENMON PID while carrying out a Wiggle Test on the wire harness.
- Does the GENMON PID read 0%?
- YES : REPAIR open connection on circuit 1817 (YE) C102a-1, and PCM C175e-26. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- NO : INSTALL a new generator. REFER to GENERATOR AND REGULATOR . CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.