Pinpoint Test Ag: DTC U0140 - Lost Communication With Body Control Module (Gem)
- AG1 RETRIEVE THE RECORDED DTCs FROM BOTH THE CONTINUOUS AND ON-DEMAND INSTRUMENT CLUSTER (IC) SELF-TESTS
- Check for recorded instrument cluster (IC) DTCs from the continuous and on-demand self-tests.
- Is DTC B1318 recorded?
- YES
: Go to Pinpoint Test AB .
- NO
: Go to AG2.
- AG2 RECHECK THE INSTRUMENT CLUSTER (IC) DTCs
- Key in ON position.
- Enter the following diagnostic mode on the diagnostic tool: Instrument Cluster (IC) Self-Test
- Clear the DTCs. Repeat the instrument cluster (IC) self-test.
- Is DTC U0140 still present?
- YES
: Go to AG3.
- NO
: The system is operating correctly at this time. The DTC may have been set due to high network traffic.
- AG3 CHECK THE AUDIO CONTROL MODULE (ACM) AND THE HEATING VENTILATION AIR CONDITIONING (HVAC) MODULE FOR DTC U0140
- Enter the following diagnostic mode on the diagnostic tool: ACM Self-Test
- Carry out the self-test on the ACM and HVAC module.
- Is DTC U0140 recorded?
- YES
: REFER to MODULE COMMUNICATIONS NETWORK
article to diagnose no communication with the SJB.
- NO
: Go to AG4.
- AG4 CHECK FOR CORRECT INSTRUMENT CLUSTER (IC) OPERATION
- Disconnect the instrument cluster (IC) connector.
- Check for:
- Connect the instrument cluster (IC) connector and make sure it seats correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- YES
: INSTALL a new instrument cluster (IC). REFER to Instrument Cluster (IC) . TEST the system for normal operation.
- NO
: The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.