LEMON Manuals: Even more car manuals for everyone
Home >> Mercury >> 2008 >> Milan Base, 3.0 1, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 846 (Climate Control System - General Information And Diagnostics - F250-F550) >> Diagnostic Tests >> Climate Control System >> Pinpoint Tests >> Pinpoint Test O: No Operation In High Blower Setting - Manual Climate Control >> Pinpoint Test O: No Operation In High Blower Setting - Manual Climate Control

Pinpoint Test O: No Operation In High Blower Setting - Manual Climate Control

WARNING: This page is about a different car, the 2007 Ford Pickup, 2007 Ford F550 Super Duty, 2007 Ford F450 Super Duty, and 2007 Ford Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.
  1. O1 CHECK CIRCUIT 261 (OG/BK) FOR AN OPEN CIRCUIT 
    • Key in OFF position.
    • Disconnect: Blower Motor Switch C294c
    • Key in ON position.
    • Turn the function selector switch to the FLOOR position.
    • Fig 1: Checking Circuit For Open
      GF0007972Courtesy of FORD MOTOR CO.
    • Measure the voltage between blower motor switch connector C294c-2, circuit 261 (OG/BK) and ground.
    • Is the voltage greater than 10 volts? 
    1. YES  : INSTALL a new blower motor switch. REFER to CLIMATE CONTROL article. TEST the system for normal operation.
    2. NO  : REPAIR circuit 261 (OG/BK) for an open circuit. TEST the system for normal operation.