LEMON Manuals: Even more car manuals for everyone
Home >> Mercury >> 2008 >> Milan Base, 3.0 1, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 386 (Exterior Lighting System) >> Diagnosis And Testing >> Autolamps >> Pinpoint Tests >> Pinpoint Test H: The Autolamps Are Inoperative >> Normal Operation

Normal Operation

WARNING: This page is about a different car, the 2006 Mercury Mariner and 2006 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.

The smart junction box (SJB) sends a reference signal to the multifunction switch through circuit 1399 (DB/WH) and a signal to the light sensor through circuit 7 (LG/YE). Ground for the light sensor is sent through circuit 570 (BK/WH). When the multifunction switch is switched to the autolamps ON position, the voltage signal is routed to ground through circuit 570 (BK/WH). When the SJB detects the multifunction switch in the autolamps ON position, the SJB sends out voltage to the exterior lamps if the ambient light conditions are dark. The light sensor determines the amount of light based on the input received from the ambient sky conditions. When the ambient level has reached a point (determined by the internal programming of the SJB), the SJB sends voltage to the headlamps, license lamps and parking lamps.