Pinpoint Test J: The Doors Do Not Lock/Unlock Using The Keyless Entry Keypad
WARNING: This page is about a different car, the 2009 Mercury Milan, 2009 Lincoln MKZ, and 2009 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- J1 CHECK THE SJB KEYCODE PID
- Enter the following diagnostic mode on the diagnostic tool: SJB DataLogger
- Observe the SJB PID (KEYCODE). Read and record the 5-digit factory set entry code.
- Enter the 5-digit factory set entry code on the keyless entry keypad, then press the 3/4 button.
- Do the doors unlock?
- YES : The system is operating as designed. INFORM the customer of the correct system operation.
- NO : Go to J2.
- J2 RETRIEVE THE RECORDED SJB DTCs FROM THE ON-DEMAND SELF-TEST
- Check for recorded SJB DTCs from the on-demand self-test.
- Is DTC B2695, B2696, or B2697 recorded?
- J3 REPEAT THE SJB ON-DEMAND SELF-TEST
- Disconnect: Keyless Entry Keypad C530
- Clear the DTCs, then repeat the SJB on-demand self-test.
- Is DTC B26956, B2696, or B2697 recorded?
- YES : Go to J4.
- NO : INSTALL a new keyless entry keypad. REFER to Keyless Entry Keypad . CLEAR the DTCs. REPEAT the self-test.
- J4 CHECK CIRCUITS CPK29 (GY/BU), CPK30 (VT/GN) AND CPK31 (YE/GN) FOR A SHORT TO GROUND
- Key in OFF position.
- Disconnect: SJB C2280c
- Measure the resistance between the keypad, harness side and ground as follows:
Keypad Connector-Pin Circuit C530-7 CPK29 (GY/BU) C530-5 CPK30 (VT/GN) C530-1 CPK31 (YE/GN) - Are the resistances greater than 10,000 ohms?
- YES : Go to J10.
- NO : REPAIR the circuit in question. CLEAR the DTCs. REPEAT the self-test.
- J5 CHECK THE SJB KEY_PAD PID
- Enter the following diagnostic mode on the diagnostic tool: SJB DataLogger
- Press each keyless entry keypad button while observing the SJB PID (KEY_PAD).
- Does the PID display the correct values?
- J6 CHECK CIRCUIT GD126 (BK/WH) FOR AN OPEN
- Key in OFF position.
- Disconnect: Keyless Entry Keypad C530
- Measure the resistance between the keyless entry keypad C530-2, circuit GD126 (BK/WH), harness side and ground.
- Is the resistance less than 5 ohms?
- YES : Go to J7.
- NO : REPAIR the circuit. TEST the system for normal operation.
- J7 CHECK THE KEYLESS ENTRY KEYPAD
- Connect a fused (5A) jumper wire between the keyless entry keypad harness side, while monitoring the SJB PID (KEY_PAD) as follows:
Keyless Entry Keypad Connector-Pin/ Circuit Keyless Entry Keypad Connector-Pin/ Circuit SJB PID (KEY_PAD) Value C530-7
CPK29 (GY/BU)C530-2
GD126 (BK/WH)1/2 C530-5
CPK30 (VT/GN)C530-2
GD126 (BK/WH)7/8 C530-1
CPK31 (YE/GN)C530-2
GD126 (BK/WH)9/0 - Does the PID display the correct values?
- YES : INSTALL a new keyless entry keypad. REFER to Keyless Entry Keypad .
- NO : Go to J8.
- Connect a fused (5A) jumper wire between the keyless entry keypad harness side, while monitoring the SJB PID (KEY_PAD) as follows:
- J8 CHECK CIRCUITS CPK29 (GY/BU), CPK30 (VT/GN) AND CPK31 (YE/GN) FOR AN OPEN
- Disconnect: SJB C2280c
- Measure the resistance between the SJB, harness side and the keyless entry keypad, harness side as follows:
SJB Connector-Pin Circuit Keyless Entry Keypad Connector-Pin C2280c-15 CPK29 (GY/BU) C530-7 C2280c-16 CPK30 (VT/GN) C530-5 C2280c-21 CPK31 (YE/GN) C530-1 - Are the resistances less than 5 ohms?
- YES : Go to J9.
- NO : REPAIR the circuit in question. TEST the system for normal operation.
- J9 CHECK CIRCUITS CPK29 (GY/BU), CPK30 (VT/GN) AND CPK31 (YE/GN) FOR A SHORT TO EACH OTHER
- Measure the resistance between the keypad, harness side as follows:
Keypad Connector-Pin Circuits Keypad Connector-Pin C530-7 CPK29 (GY/BU) and CPK30 (VT/GN) C530-5 C530-7 CPK29 (GY/BU) and CPK31 (YE/GN) C530-1 C530-5 CPK30 (VT/GN) and CPK31 (YE/GN) C530-1 - Are the resistances greater than 10,000 ohms?
- YES : Go to J10.
- NO : REPAIR the circuit in question. TEST the system for normal operation.
- Measure the resistance between the keypad, harness side as follows:
- J10 CHECK FOR CORRECT SJB OPERATION
- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- YES : INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES article. CYCLE each IKT key to the ON position for a minimum of 6 seconds to program the RKE function of the integrated keys. TEST the system for normal operation.
- NO : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.