Inspection and Verification
- Verify the customer concern by operating the system.
- Visually inspect for obvious signs of mechanical or electrical damage.
Visual Inspection Chart
VISUAL INSPECTIONMechanical Electrical - Sticking or binding illumination dimmer
- Blown battery junction box (BJB) Fuse:
- F4 (15A)
- Blown central junction box (CJB) Fuse:
- F52 (10A)
- F59 (7.5A)
- Damaged wiring harness
- Loose or corroded connectors
- Damaged illumination dimmer
- Damaged tail lamp relay
- Damaged switch(es)
- Damaged miniature bulb(s)
- Damaged Joint Connector 2 shorting strips
- Damaged Joint Connector 3 shorting strips
- If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step.
- If the concern is not visually evident, determine the symptom and refer to the Symptom Chart .