Self-Diagnostic System

To enter Hybrid Electronic Cluster (HEC) self-diagnostics, press instrument cluster trip odometer reset button before turning ignition switch to RUN position. Within 5-8 seconds, odometer will display "tESt". Trip odometer reset button must be released within 3 seconds of odometer displaying "tESt" then, repeatedly press trip odometer reset button through odometer displays. Press trip odometer reset button again and any continuous diagnostic trouble codes will be displayed before odometer advances to next display. See HYBRID ELECTRONIC CLUSTER SELF-DIAGNOSTIC MODES  table. To exit instrument cluster self-test mode, turn ignition switch to LOCK position.

HYBRID ELECTRONIC CLUSTER SELF-DIAGNOSTIC MODES (1)

Odometer Display Description
GAGE Activates Sweep Of All Gauges: Displays Present Gauge Values; Performs ROM & EE Checksum Tests
All Segments Illuminated Carries Out A Gauge Sweep Of All Gauges To 45° From Rest Position; Illuminates All Odometer Segments
bulb Illuminates LOW FUEL Warning Light
r Returns To Normal Operation All Micro-Controlled Lights & Leds; Displays Hexadecimal Values For ROM.
nr Displays Hexadecimal Value For ROM Level Type MSP & LSB As Stored In VNM
EE Displays Hexadecimal Value For EE; Flashes Alternating FAIL & EE Level Messages
dt Displays Hexadecimal Coding Of Final Manufacturing Test Date
CF1 Displays Hex Coding Of A1tec NVM Module Configuration Settings; English/Metric units 1=English base/RPO; 1=RPO
E ####.# Displays English Speed Value Being Input; Speedometer Will Indicate Present Speed
Blank #### Displays Metric Speed Value Being Input; Speedometer Will Indicate Present Speed
t #### Displays Tachometer Value Being Input To Instrument Cluster; Tachometer Will Indicate Present RPM; Display Will Show 0 If Input Is Not Received, If Input Received Is Invalid For One Second Or More Or If Speed Is 0
F ### Displays Present Fuel Level Being Input To Instrument Cluster As A Ratio; If Value Displayed Is 255, Circuit Is Open. If Value Displayed Is 000-009, Circuit Is Shorted; Normal Range Will Be 10-254; If Value Displayed Is 250, Gauge Should Read Full. If Value Displayed Is 30, Gauge Should Read Empty
FP ### Displays present fuel level percent status in decimals. Display will read between 0 and 254 for normal range with 255 indicating an open or short.
### C Displays Present Temperature Analog/Digital Input Ration In Decimal Value; Temperature Gauge Will Indicate Present Temperature; Normal Range Is 0-255; Values Decrease As Temperature Increases
Ot ### Displays Outside Air Temperature Analog/Digital Input In Decimals; OAT Display Will Indicate Present OAT (RPO Cluster Only); Short Circuit Range Is From 000-009; Normal Range Is 10-254
blank ##.# Displays Stored Odometer Value In NVM miles; If NVM For Odometer Is Corrupt, ERROR Will Be Displayed
bAtt Will Indicate Battery Reference Voltage Reading In Volts
HSd Displays Present Status Of High Voltage Shutdown; 0 = Voltage Not High; 1 = Over Voltage Shutdown
HLP Displays Input Status Of Headlight Switch; P = Headlights On (Pulse Width Modulation); O = Headlights Off (Open)
PA Displays 8-Bit Hexadecimal Value For Port "A" Readings
Pb Displays 8-Bit Hexadecimal Value For Port "B" Readings
PE Displays 8-Bit Hexadecimal Value For Port "E" Readings
Pd Displays 7-Bit Hexadecimal Value For Port Dlc Readings
PS Displays 8-Bit Hexadecimal Value For Port "S" Readings
PT Displays 8-Bit Hexadecimal Value For Port "T" Readings
PP Displays 8-Bit Hexadecimal Value For Port "P" Readings
(1) Values displayed are instrument cluster input values, not gauge values.