Test Z: Turn & High Beam Indicators Never/Always On
- Turn ignition off. Remove instrument cluster. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. Disconnect instrument cluster connector C276. See Figure . Measure resistance between ground and instrument cluster connector C276 terminal No. 19 (Black wire). If resistance is 5 ohms or less, replace instrument cluster. See INSTRUMENT CLUSTER under REMOVAL & INSTALLATION. If resistance is more than 5 ohms, go to next step.
- Leave ignition off. Remove Green diode strip from junction box No. 2 and connector C2010. See Figure and Figure . Measure resistance of Black wire between instrument cluster connector C276 terminal No. 19 and diode junction box No. 2 connector C2010 terminal No. 14. If resistance is less than 5 ohms, go to next step. If resistance is 5 ohms or more, repair open in Black wire.
- Leave ignition off and Green diode strip removed from junction box No. 2. Measure resistance between ground and diode junction box No. 2 connector C2010 terminal No. 15 (Black wire). If resistance is less than 5 ohms, replace Green Diode strip. If resistance is 5 ohms or more, repair open in Black and/or Black/Red wire. See WIRING DIAGRAMS .