Test N: Turn & High Beam Indicators Inoperative
- Turn ignition off. Remove instrument cluster. See INSTRUMENT CLUSTER in REMOVAL & INSTALLATION. Disconnect instrument cluster connectors C266 and C270. Measure resistance between ground and instrument cluster connectors C266 terminal No. 1 and C270 terminal No. 1 (Black wires). See Figure - Figure . If resistance is less than 5 ohms, replace instrument cluster printed circuit. Refer to PRINTED CIRCUIT under REMOVAL & INSTALLATION. Retest system. If resistance is 5 ohms or more, go to next step.
- Remove Green diode strip from diode junction box located behind fuse panel. Measure resistance of Black wire between instrument cluster connectors C266 terminal No. 1 and diode junction box No. 2 connector terminal No. 32. See Figure . Measure resistance of Black wire between instrument cluster connectors C270 terminal No. 1 and diode junction box No. 2 connector C2010 terminal No. 14. If resistance in both measurements is less than 5 ohms, go to next step. If resistance in either measurement is 5 ohms or more, repair open in appropriate Black wire.
- Measure resistance between ground and diode junction box No. 2 connector terminals No. 15 and No. 33 (Black wires). If resistance in both measurements is less than 5 ohms, replace Green diode strip. If resistance in either measurement is 5 ohms or more, repair open in appropriate Black wire.