Instrument Panel Reinforcement Bar: Removal
- Remove the instrument panel. Refer to the procedure in this section.
- Remove the left hand register duct screw and the left hand register duct.
- Remove the two center register duct screws and the center register duct.
- Remove the right hand register duct screw and the right hand register duct.
- Remove the two floor duct screws and the floor duct.
- Remove the oil level timer module from its bracket.
- Separate the electrical harness from the instrument panel reinforcement bar.
- Separate the antenna cable and the diversity antenna wire, if equipped, from the instrument panel reinforcement bar.
- Remove the two U-bracket ground bolts and the ground wires.
- Loosen the Powertrain Control Module (PCM) electrical connector bolt and disconnect the PCM electrical connector.
- Loosen the Transaxle Control Module (TCM) electrical connector bolt and disconnect the TCM electrical connector.
- Remove the two PCM/TCM bracket bolts and remove the PCM and the TCM.
- Remove the interior fuse panel screw.
- Remove the two parking brake release lever screws.
- Remove the shift-lock relay/flasher module bracket screw.
- Remove the heater unit housing-to-instrument panel reinforcement bar bolt.
- Separate the harness from the U-bracket.
- Remove the ABS control module bracket screw.
- Remove the three U-bracket-to-chassis nuts.
- Remove the four U-bracket bolts and remove the U-bracket.
- Remove the two left hand and the two right hand console bracket bolts and the console brackets.
- Remove the two right hand reinforcement bar nuts.
- Remove the two left hand reinforcement bar bolts and the two nuts.
- Remove the four reinforcement bar upper bolts.
- Remove the instrument panel reinforcement bar.
CAUTION:
Electronic modules are sensitive to static electrical charges. If exposed to these charges, damage may result. See Module Servicing Procedures in ELECTRICAL DISTRIBUTION.
CAUTION:
Electronic modules are sensitive to static electrical charges. If exposed to these charges, damage may result. See Module Servicing Procedures in ELECTRICAL DISTRIBUTION.