Switches, Gauges & Instrument Panels: Testing: Gauges: Ammeter
Turn headlights to "ON" position and ignition to "OFF" position. Meter pointer should move toward the "D" or discharge side of the gauge. If no pointer movement is noted, check the following: Rear of meter housing for loose connections, printed circuit connections, multiple connector at printed circuit. If connections are good replace ammeter.