Pinpoint Test D: A Single Power Window Is Inoperative - RH Front
WARNING: This page is about a different car, the 2009 Ford Pickup, 2009 Ford F550 Super Duty, 2009 Ford F450 Super Duty, and 2009 Ford Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.
- D1 CHECK THE VOLTAGE TO THE RH FRONT WINDOW CONTROL SWITCH
- Disconnect: RH Front Window Control Switch C604
- Key in ON position.
- For regular cab and SuperCab, measure the voltage between RH front window control switch C604-3, circuit CBP47 (GN/BU) harness side and ground.
- For Crew Cab, measure the voltage between RH front window control switch C604-3, circuit CPW14 (VT/WH) harness side and ground.
- Is the voltage greater than 10 volts?
NOTE: For Crew Cab, set the window lock switch to the unlock position. - D2 CHECK CIRCUIT CPW14 (VT/WH) FOR AN OPEN
- Key in OFF position.
- Disconnect: LH Front Window Control Switch C504b
- Measure the resistance between LH front window control switch C504b-2, circuit CPW14 (VT/WH) harness side and RH front window control switch C604-3, circuit CPW14 (VT/WH) harness side.
- Is the resistance less than 5 ohms?
- YES : INSTALL a new LH front window control switch. REFER to Window Control Switch . TEST the system for normal operation.
- NO : REPAIR the circuit(s). TEST the system for normal operation.
- D3 CHECK CIRCUIT CPW12 (GN/OG) AND CIRCUIT CPW13 (BN/YE) FOR CONTINUITY TO GROUND
- Key in OFF position.
- Measure the resistance between RH front window control switch C604-1 circuit CPW12 (GN/OG) harness side and ground; and between RH front window control switch C604-6, circuit CPW13 (BN/YE) harness side and ground.
- Are the resistances less than 5 ohms?
Courtesy of FORD MOTOR CO.
- D4 CHECK CIRCUIT CPW12 (GN/OG) AND CIRCUIT CPW13 (BN/YE) FOR AN OPEN
- Disconnect: LH Front Window Control Switch C504a (Crew Cab) or C504b (Regular and SuperCab)
- Measure the resistance between LH front window control switch C504a-3 (Crew Cab) or C504b-3 (regular and SuperCab), circuit CPW12 (GN/OG) harness side and RH front window control switch C604-1, circuit CPW12 (GN/OG) harness side.
- Measure the resistance between LH front window control switch C504a-8 (Crew Cab) or C504b-8 (regular and SuperCab), circuit CPW13 (BN/YE) harness side and RH front window control switch C604-6, circuit CPW13 (BN/YE) harness side.
- Is the resistance less than 5 ohms?
Fig 4: Measuring Resistance Between LH Front Window Control Switch C504A-3 (Crew Cab) Or C504B-3 (Regular & SuperCab)Courtesy of FORD MOTOR CO.
Fig 5: Measuring Resistance Between LH Front Window Control Switch C504A-8 (Crew Cab) Or C504B-8 (Regular & SuperCab)Courtesy of FORD MOTOR CO.
- YES : INSTALL a new LH front window control switch. REFER to Window Control Switch . TEST the system for normal operation.
- NO : REPAIR the circuit(s). TEST the system for normal operation.
- D5 CHECK THE RH FRONT WINDOW CONTROL SWITCH
- Key in ON position.
- Connect a 30A fused jumper wire between RH front window control switch C604-1, circuit CPW12 (GN/OG) and RH front window control switch C601-5, circuit CPW20 (WH/OG); and a second jumper wire between RH front window control switch C604-3, circuit CPB47 (GN/BU)/CPW14 (VT/WH) and RH front window control switch C604-2, circuit CPW19 (VT) harness side. The RH front window should move DOWN.
- Connect a 30A fused jumper wire between RH front window control switch C604-6, circuit CPW13 (BN/YE) and RH front window control switch C604-2, circuit CPW19 (VT); and a second jumper wire between RH front window control switch C604-3, circuit CPB47 (GN/BU)/CPW14 (VT/WH) and RH front window control switch C604-5, circuit CPW20 (WH/OG) harness side. The RH front window should move UP.
- Does the window operate correctly?
- YES : If the RH front window did not operate with the RH front window controls, INSTALL a new RH front window regulator control switch. If the RH front power window did operate with the RH front window control switch but not with the LH front window control switch, INSTALL a new LH front window control switch. REFER to Window Control Switch . TEST the system for normal operation.
- NO : Go to D6.
- D6 CHECK CIRCUIT CPW20 (WH/OG) AND CIRCUIT CPW19 (VT) FOR AN OPEN
- Key in OFF position.
- Disconnect: RF Window Motor C608
- Measure the resistance between RH front window control switch C604-5, circuit CPW20 (WH/OG) harness side and RH front window motor C608-1, circuit CPW20 (WH/OG) harness side.
- Measure the resistance between RH window control switch C604-2, circuit CPW19 (VT) harness side and RH window motor C608-2, circuit CPW19 (VT) harness side.
- Are the resistances less than 5 ohms?
- YES : INSTALL a new RH front window motor. REFER to Window Regulator Motor - Front Door . TEST the system for normal operation.
- NO : REPAIR the circuit(s). TEST the system for normal operation.