Scrapping Pressure Reservoirs For Level Control And Hydropneumatic Suspension, Central Reservoirs For Hydropneumatic Suspension - OS32.00-P-1000-01A
Model All
with CODE (216b) Self-levelling suspension all-around, with adaptive damping system (ADS)
with CODE (217a) Self-levelling suspension on rear axle with ADS
with CODE (480) Level control system at rear
with CODE (489) Level control system all around
all
Carefully loosen gas-filler plug on domed face of central reservoir or pressure reservoir, allow gas to escape and then completely screw out gas filler plug (arrow).