LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2025 >> GLA250 Base >> Repair and Diagnosis >> External Pages >> Different car >> Section 4 (Overall Vehicle (2 Of 4) -- 118 Chassis) >> Testing & Repair >> Remove Contacts From Micro Quadlock System Coupling >> Remove Contacts From Micro Quadlock System Coupling - AR00.19-P-0120-04B

Remove Contacts From Micro Quadlock System Coupling - AR00.19-P-0120-04B

WARNING: This page does not describe the selected car, but rather 12 other vehicles, including the 2023 Mercedes-Benz CLA45 AMG, 2023 Mercedes-Benz CLA35 AMG, 2023 Mercedes-Benz CLA250, 2022 Mercedes-Benz CLA45 AMG, and 2022 Mercedes-Benz CLA35 AMG. However, it is still accessible from the selected car via links, so may be relevant.

Model All Micro-Quadlock-System coupling type 2 

Fig 1: Identifying New Passenger Vehicle Wiring Harness Repair Kit (220 589 04 99 00)
G16047542Courtesy of MERCEDES-BENZ USA
Fig 2: Identifying Wiring Harness Repair Kit, Basic (000 589 13 99 00)
G16065040Courtesy of MERCEDES-BENZ USA
Fig 3: Identifying Blade Holder With Clamping Pliers (220 589 01 99 50)
G16047544Courtesy of MERCEDES-BENZ USA
Fig 4: Identifying MQS Blade (220 589 01 99 60)
G12824586Courtesy of MERCEDES-BENZ USA

Unfasten secondary release on version with sliding plate (shown on Junior Power Timer (JPT), micro quadlock system coupling) 

  1. Using a suitable tool, move both sliding plates (1) in housing in direction of arrow over catch mechanism.
    G07715629Courtesy of MERCEDES-BENZ USA

    Unfasten secondary release on version with retaining cage (shown on MQS, Multi Contact Point coupling) 

  2. Using a suitable tool (1), slide retaining cage (2) into pre-locking position in direction shown by arrow.
    G11971209Courtesy of MERCEDES-BENZ USA

    Unpin female contacts from coupling 

  3. Insert blade holder with SPECIAL TOOL clamping pliers and SPECIAL TOOL MQS blade from front side through opening next to contact cavity of coupling.

    IMPORTANT This step presses the spring shackle on the female contact (1) down into position.

  4. A slight tug on the corresponding cable will remove the female contact (1) from the contact cavity of the coupling.
    G13769494Courtesy of MERCEDES-BENZ USA