Constants Signal List, PSM Function - GF54.21-D-3111TSA
Model 907
with code ED5 (Parameterisable special module)
Signal identification number = Signal ID.
Word = Data word.
DWord = Double data word.
CONSTANTS SIGNAL LIST, PSM FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value |
|---|---|---|---|---|
| Const_Bit_0 | 0x1000 | Constants for parameterization, bit value, always "0" | Bit | 0 |
| Const_Bit_1 | 0x1001 | Constants for parameterization, bit value, always: "1" | Bit | 1 |
| Const_Byte_0 | 0x2000 | Constants for parameterization, byte value, always "0" | Byte | 0 |
| Const_Byte_1 | 0x2001 | Constants for parameterization, byte value, always "255 (0xFF)" | Byte | 255 |
| Const_Word_0 | 0x3000 | Constants for parameterization, data word (2 bytes), fixed value: "0" | Data word (Word) | 0 |
| Const_DWord_0 | 0x4000 | Constants for parameterization, double word (DWord) (4 bytes), always "0" | Double word (DWord) | 0 |
| Const_Word_1 | 0x3001 | Constants for parameterization, data word (Word) (2 bytes), always "65 535 (0xFFFF)" | Data word (Word) | 0 |
| Const_DWord_1 | 0x4001 | Constants for parameterization, double word (DWord) (4 bytes), always "0xFFFFFFFF" | Double word (DWord) | 4 294 967 295 |
| Overview of system components for parameterizable special module (PSM) | GF54.21-D-9998TSA |