MODIFICATION NOTES

07.01.2020 Bonding surface (C2) expanded.    
REPAIR MATERIALS

Number Designation Order number
BR00.45-Z-1056-07A 1K-zinc dust paint A 000 986 28 00

IMPORTANT

The next steps are shown on the left side of the vehicle. In case of damage on the right side of the vehicle, these steps must be performed analogously.

The superordinate service document as well as the safety information in the service document must be observed.

G16051151Courtesy of MERCEDES-BENZ USA
  1. Mark separating points on A-pillar reinforcement (1) and cut (areas A, B).

    IMPORTANT

    Transfer separation points from vehicle.

  2. Grind mating surfaces on A-pillar reinforcement (1) down to bare metal in cross-hatched areas.

    IMPORTANT

    Sand down spot weld flanges to bare metal on both sides.

  3. Remove grinding dust.
  4. Apply zinc dust paint to insides of spot weld flanges. onto connecting flanges that are no longer accessible after installing side roof paneling.

    NOTES Do not coat bonding surfaces with zinc dust paint (areas C1 , C2 ).

    Otherwise adhesion problems can occur.

    IMPORTANT

    Observe pretreatment of bonding surfaces.

  5. Mark separating points on A-pillar inner section (2) and cut (areas D, E).

    IMPORTANT

    Transfer separation points from vehicle.

    G16051152Courtesy of MERCEDES-BENZ USA
    G16051153Courtesy of MERCEDES-BENZ USA
  6. Grind mating surfaces on A-pillar inner section (2) down to bare metal in cross-hatched areas.

    IMPORTANT

    Sand down spot weld flanges to bare metal on both sides.

  7. Remove grinding dust.
  8. Apply zinc dust paint to insides of spot weld flanges. onto connecting flanges that are no longer accessible after installing side roof paneling.

    NOTES Do not coat bonding surfaces with zinc dust paint (areas F1 , F2 , F3 ).

    Otherwise adhesion problems can occur.

    IMPORTANT