LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2023 >> GLA250 Base >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Climate Control System -- 247 Chassis >> Testing & Repair >> Check Air Conditioning System For Leakage - AR83.30-P-1761MFA

Check Air Conditioning System For Leakage - AR83.30-P-1761MFA

Model 118 with engine 139, 260, 282, 608, 654 

Model 177 with engine 139, 260, 282, 608, 654 

Model 247 with engine 260, 282, 608, 654 

Model 247.7 with engine 139 

DANGER Risk of explosion  when using a forming gas with incorrect mixing ratio. Risk of suffocation due to inhalation of forming gas. Risk of injury  due to bursting of high-pressure hoses. Wear safety glasses and protective gloves. No smoking or open flames. Work in well-ventilated rooms only. AS83.00-Z-0001-02A 
Notice  Procedure for a damaged or leaky air conditioning system   AH83.30-P-0004-01KOA 
INSPECT Check     
1 Evacuate air conditioning system.   AR83.30-P-1760MFA 
2 Fill air conditioning with forming gas and check pressure drop.    
REFER TO SPECIAL TOOLS 000 588 37 21 00 Leak tester IMPORTANT Pay attention to the leak tester operator's manual.
IMPORTANT Do not fill air conditioning system with forming gas unless engine is cold.
IMPORTANT Temperature changes during the pressure test (e.g. due to weather change or cooling down of the engine compartment overnight) can cause pressure fluctuations. Consistent ambient conditions must therefore be strictly ensured.
WS83.00-P-0067B 
    HAND-HELD TESTER Pressure drop in refrigerant circuit filled with test gas *BE83.30-P-1001-04A 
3 Check for leakage on air conditioning system using gas detection unit. If a pressure drop is detected.  
REFER TO SPECIAL TOOLS 000 588 31 21 00 Gas detection unit IMPORTANT Pay attention to the operator's manual of the leak tester and the gas detection unit.
If a leakage is found,

Replace damaged components of the air conditioning system.
WS47.00-P-0077B
4 Release forming gas from leak tester.    
5 Fill air conditioning.   AR83.30-P-1760MFA 
AIR CONDITIONING

Number Designation Model 118, 164, 166, 167, 169, 171, 177, 190, 197, 199, 204, 205, 206, 207, 209, 211, 212, 214, 216, 218, 219, 221, 230, 238, 240, 243, 245, 247, 251, 253, 257, 290, 292, 293 Model 213, 217, 222 except code 1U6 (R744 refrigerant)
BE83.30-P-1001-04A Pressure drop in refrigerant circuit filled with test gas Test pressure bar 15
Test period h 4
Permissible fluctuation of ambient temperature °C ±2
Pressure drop bar 0