Home >> Mercedes Benz >> 2021 >> Sprinter 1500 Van Passenger >> Repair and Diagnosis >> Body & Frame >> Body, Cab Control Systems >> ELECTRICAL SYSTEM, EQUIPMENT & INSTRUCTIONS - BASIC KNOWLEDGE (1 of 2) >> Basic Knowledge >> Signal List, Caravan Control Unit, Battery Management, Function - GF54.21-D-5058TSA

Signal List, Caravan Control Unit, Battery Management, Function - GF54.21-D-5058TSA

Model 907 

with code JA3 (Intelligent body control.) 

SIGNAL LIST FOR BATTERY MANAGEMENT LIN CONNECTIONS

Signal ID Signal type/number Signal: Name/function Parameter
  Byte Bit    
03CH 1 0 Name: MasterReqB0 Value/function:
0/SLEEP MODE COMMAND
1/DIAGNOSTIC ADDRESS 'HEIZUNG TRUMA' (1h)
2/DIAGNOSTIC ADDRESS 'SRV' (2h)
3/DIAGNOSTIC ADDRESS 'KLADometic' (3h)
5/DIAGNOSTIC ADDRESS 'BSH' (5h)
6/DIAGNOSTIC ADDRESS 'LRD' (6h)
8/DIAGNOSTIC ADDRESS 'THETFORD' (8h)
16/DIAGNOSTIC ADDRESS 'HEIZUNG ALDE' (10h)
25/DIAGNOSTIC ADDRESS 'SAT' (19h)
  2 0 Name: MasterReqB1 -
  3 0 Name: MasterReqB2 -
  4 0 Name: MasterReqB3 -
  5 0 Name: MasterReqB4 -
  6 0 Name: MasterReqB5 -
  7 0 Name: MasterReqB6 -
  8 0 Name: MasterReqB7 -
SIGNAL LIST FOR BATTERY MANAGEMENT LIN CONNECTIONS

Signal ID Signal type/number Signal: Name/function Parameter
  Byte Bit    
021h 1 0 Name: RsErr_BSH_IBS
Function: LIN standard flag which indicates that an error occurred during the previous transmission.
File type: 01_BSH_LINRespErr
Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv
1/FLAG_ACTIVE/Flag aktiv
  1 1 Name: BSH_WakeupStat
Function: Information as to whether the intelligent battery sensor (IBS) has woken up the master or not.
File type: 02_BSH_WakeupStat
Value/name/function: 0/No_Active_Wakeup_Demand/keine aktive Wake-up Anforderung
1/Active_Wakeup_Demand/aktive Wake-up Anforderung
2/not defined
  1 3 Name: BSH_Event_LowVoltage
Function: Voltage lower than defined level
File type: 01_BSH_Event_LowVoltage
Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv
1/FLAG_ACTIVE/Flag aktiv
  1 4 Name: BSH_Event_PowerOn
Function: IBS switch-on in the last 2 seconds
File type: 01_BSH_Event_PowerOn
Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv
1/FLAG_ACTIVE/Flag aktiv
  1 5 Name: BSH_Event_EngineStart
Function: Engine running determined
File type: 01_BSH_Event_EngineStart
Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv
1/FLAG_ACTIVE/Flag aktiv
  1 6 Name: BSH_Sulfation
Function: Flag for battery sulfate formation
File type: 01_BSH_Sulfation
Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv
1/FLAG_ACTIVE/Flag aktiv
  1 7 Name: BSH_BatteryDefect
Function: Battery fault flag
File type: 01_BSH_BatteryDefect
Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv
1/FLAG_ACTIVE/Flag aktiv
  2 0 Name: BSH_SOCUpperTolerance
Function: State of charge, upper tolerance
File type: 08_BSH_SOCUpperTolerance
Value/range/increment: 0...254/0...254 %/1 %
  3 0 Name: BSH_SOCLowerTolerance
Function: State of charge, lower tolerance
File type: 08_BSH_SOCLowerTolerance
Value/range/increment: 0...254/0...254 %/1 %
  4 0 Name: BSH_CapacityLossTop
Function: Loss of upper capacity (reversible)
File type: 08_BSH_CapacityLossTop
Value/range/increment: 0...200/0...100 %/0,5 %
  5 0 Name: BSH_CapacityLossBottom
Function: Lower capacity loss
File type: 08_BSH_CapacityLossBottom
Value/range/increment: 0...200/0...100 %/0,5 %
022h 1 0 Name: BSH_BatteryCurrent
Function: Battery current (charge: positive)
File type: 24_BSH_BatteryCurrent
Value/range/increment: 0...4,000,000/-2,000,000...2,000,000 mA/1 mA
  4 0 Name: BSH_BatteryVoltage
Function: Battery voltage
File type: 16_BSH_Batteryvoltage
Value/range/increment: 0...50,000/0...50 mV/0.001 mV
  6 0 Name: BSH_BatteryTemperature
Function: Battery temperature
File type: 09_BSH_BatteryTemp
Value/range/increment: 0...330/-40...125 °C/0.5 °C
  7 1 Name: BSH_CurrentAutorange
Function: Current measuring range (reinforcement adjustment)
File type: 02_BSH_CurrentAutorange
Value/name/function (tolerance): 0/Range_Not_Defined/nicht definiert
1/Current_range_l1/Bereich l1 (± 1 A)
2/Current_range_l2/Bereich l2 (± 1500 A)
2/Current_range_l3/Bereich l3 (not used)
  7 7 Name: BSH_IBS_Error
Function: global IBS fault flag
File type: 01_BSH_IBS_Error
Value/name/function: 1/FLAG_ACTIVE/Flag aktiv
025h 1 0 Name: BSH_StateOfCharge
Function: State of charge
File type: 08_BSH_StateOfCharge
Value/range/increment: 0...200/0...100 %/0,5 %
  2 0 Name: BSH_StateOfHealth
Function: Condition and age of battery
File type: 08_BSH_StateOfHealth
Value/range/increment: 0...200/0...100 %/0,5 %
  3 0 Name: BSH_EstVoltaDrop
Function: Recommended battery charging voltage
File type: 08_BSH_EstVoltaDrop
Value/range/increment: 0...254/0...12.7 V/0.05 V
  4 0 Name: BSH_OptChargeVolt
Function: Optimum battery charging voltage
File type: 08_BSH_OptChargeVolt
Value/range/increment: 0...254/5...17.7 V/0.05 V
  5 0 Name: BSH_AvgRi
Function: average internal resistance
File type: 16_BSH_AvgRi
Value/range/increment: 0...20,000/0...200 Mn/0.01 mn
026h 1 0 Name: BSH_AvailableCapacity
Function: Available capacity if the rechargeable battery is fully charged.
File type: 16_BSH_AvailableCapacity
Value/range/increment: 0...5000/0...500 Ah/0.1 Ah
  3 0 Name: BSH_DischargableAh
Function: Discharge capacity
File type: 16_BSH_DischargableAh
Value/range/increment: 0...5000/0...500 Ah/0.1 Ah
  5 0 Name: BSH_NominalCapacity
Function: set rated capacity
File type: 08_BSH_NominalCapacity
Value/range/increment: 0...250/0...500 Ah/2 Ah
  6 0 Name: BSH_Recalibrated
Function: Flag for SOC valid
File type: 01_BSH_Recalibrated
Value/name/function: 0/Not_Recalibrated/nicht neu kalibriert
1/Recalibrated/neu kalibriert
03DH 1 0 Name: SlaveRespB0 Value/function: 5/DIAGNOSTIC ADDRESS 'BSH' (5h)
  2 0 Name: SlaveRespB1 -
  3 0 Name: SlaveRespB2 -
  4 0 Name: SlaveRespB3 -
  5 0 Name: SlaveRespB4 -
  6 0 Name: SlaveRespB5 -
  7 0 Name: SlaveRespB6 -
  8 0 Name: SlaveRespB7 -