Signal List, Caravan Control Unit, Battery Management, Function - GF54.21-D-5058TSA
Model 907
with code JA3 (Intelligent body control.)
SIGNAL LIST FOR BATTERY MANAGEMENT LIN CONNECTIONS
| Signal ID | Signal type/number | Signal: Name/function | Parameter | |
|---|---|---|---|---|
| Byte | Bit | |||
| 03CH | 1 | 0 | Name: MasterReqB0 | Value/function: 0/SLEEP MODE COMMAND 1/DIAGNOSTIC ADDRESS 'HEIZUNG TRUMA' (1h) 2/DIAGNOSTIC ADDRESS 'SRV' (2h) 3/DIAGNOSTIC ADDRESS 'KLADometic' (3h) 5/DIAGNOSTIC ADDRESS 'BSH' (5h) 6/DIAGNOSTIC ADDRESS 'LRD' (6h) 8/DIAGNOSTIC ADDRESS 'THETFORD' (8h) 16/DIAGNOSTIC ADDRESS 'HEIZUNG ALDE' (10h) 25/DIAGNOSTIC ADDRESS 'SAT' (19h) |
| 2 | 0 | Name: MasterReqB1 | - | |
| 3 | 0 | Name: MasterReqB2 | - | |
| 4 | 0 | Name: MasterReqB3 | - | |
| 5 | 0 | Name: MasterReqB4 | - | |
| 6 | 0 | Name: MasterReqB5 | - | |
| 7 | 0 | Name: MasterReqB6 | - | |
| 8 | 0 | Name: MasterReqB7 | - | |
SIGNAL LIST FOR BATTERY MANAGEMENT LIN CONNECTIONS
| Signal ID | Signal type/number | Signal: Name/function | Parameter | |
|---|---|---|---|---|
| Byte | Bit | |||
| 021h | 1 | 0 | Name: RsErr_BSH_IBS Function: LIN standard flag which indicates that an error occurred during the previous transmission. |
File type: 01_BSH_LINRespErr Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv 1/FLAG_ACTIVE/Flag aktiv |
| 1 | 1 | Name: BSH_WakeupStat Function: Information as to whether the intelligent battery sensor (IBS) has woken up the master or not. |
File type: 02_BSH_WakeupStat Value/name/function: 0/No_Active_Wakeup_Demand/keine aktive Wake-up Anforderung 1/Active_Wakeup_Demand/aktive Wake-up Anforderung 2/not defined |
|
| 1 | 3 | Name: BSH_Event_LowVoltage Function: Voltage lower than defined level |
File type: 01_BSH_Event_LowVoltage Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv 1/FLAG_ACTIVE/Flag aktiv |
|
| 1 | 4 | Name: BSH_Event_PowerOn Function: IBS switch-on in the last 2 seconds |
File type: 01_BSH_Event_PowerOn Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv 1/FLAG_ACTIVE/Flag aktiv |
|
| 1 | 5 | Name: BSH_Event_EngineStart Function: Engine running determined |
File type: 01_BSH_Event_EngineStart Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv 1/FLAG_ACTIVE/Flag aktiv |
|
| 1 | 6 | Name: BSH_Sulfation Function: Flag for battery sulfate formation |
File type: 01_BSH_Sulfation Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv 1/FLAG_ACTIVE/Flag aktiv |
|
| 1 | 7 | Name: BSH_BatteryDefect Function: Battery fault flag |
File type: 01_BSH_BatteryDefect Value/name/function: 0/FLAG_INACTIVE/Flag inaktiv 1/FLAG_ACTIVE/Flag aktiv |
|
| 2 | 0 | Name: BSH_SOCUpperTolerance Function: State of charge, upper tolerance |
File type: 08_BSH_SOCUpperTolerance Value/range/increment: 0...254/0...254 %/1 % |
|
| 3 | 0 | Name: BSH_SOCLowerTolerance Function: State of charge, lower tolerance |
File type: 08_BSH_SOCLowerTolerance Value/range/increment: 0...254/0...254 %/1 % |
|
| 4 | 0 | Name: BSH_CapacityLossTop Function: Loss of upper capacity (reversible) |
File type: 08_BSH_CapacityLossTop Value/range/increment: 0...200/0...100 %/0,5 % |
|
| 5 | 0 | Name: BSH_CapacityLossBottom Function: Lower capacity loss |
File type: 08_BSH_CapacityLossBottom Value/range/increment: 0...200/0...100 %/0,5 % |
|
| 022h | 1 | 0 | Name: BSH_BatteryCurrent Function: Battery current (charge: positive) |
File type: 24_BSH_BatteryCurrent Value/range/increment: 0...4,000,000/-2,000,000...2,000,000 mA/1 mA |
| 4 | 0 | Name: BSH_BatteryVoltage Function: Battery voltage |
File type: 16_BSH_Batteryvoltage Value/range/increment: 0...50,000/0...50 mV/0.001 mV |
|
| 6 | 0 | Name: BSH_BatteryTemperature Function: Battery temperature |
File type: 09_BSH_BatteryTemp Value/range/increment: 0...330/-40...125 °C/0.5 °C |
|
| 7 | 1 | Name: BSH_CurrentAutorange Function: Current measuring range (reinforcement adjustment) |
File type: 02_BSH_CurrentAutorange Value/name/function (tolerance): 0/Range_Not_Defined/nicht definiert 1/Current_range_l1/Bereich l1 (± 1 A) 2/Current_range_l2/Bereich l2 (± 1500 A) 2/Current_range_l3/Bereich l3 (not used) |
|
| 7 | 7 | Name: BSH_IBS_Error Function: global IBS fault flag |
File type: 01_BSH_IBS_Error Value/name/function: 1/FLAG_ACTIVE/Flag aktiv |
|
| 025h | 1 | 0 | Name: BSH_StateOfCharge Function: State of charge |
File type: 08_BSH_StateOfCharge Value/range/increment: 0...200/0...100 %/0,5 % |
| 2 | 0 | Name: BSH_StateOfHealth Function: Condition and age of battery |
File type: 08_BSH_StateOfHealth Value/range/increment: 0...200/0...100 %/0,5 % |
|
| 3 | 0 | Name: BSH_EstVoltaDrop Function: Recommended battery charging voltage |
File type: 08_BSH_EstVoltaDrop Value/range/increment: 0...254/0...12.7 V/0.05 V |
|
| 4 | 0 | Name: BSH_OptChargeVolt Function: Optimum battery charging voltage |
File type: 08_BSH_OptChargeVolt Value/range/increment: 0...254/5...17.7 V/0.05 V |
|
| 5 | 0 | Name: BSH_AvgRi Function: average internal resistance |
File type: 16_BSH_AvgRi Value/range/increment: 0...20,000/0...200 Mn/0.01 mn |
|
| 026h | 1 | 0 | Name: BSH_AvailableCapacity Function: Available capacity if the rechargeable battery is fully charged. |
File type: 16_BSH_AvailableCapacity Value/range/increment: 0...5000/0...500 Ah/0.1 Ah |
| 3 | 0 | Name: BSH_DischargableAh Function: Discharge capacity |
File type: 16_BSH_DischargableAh Value/range/increment: 0...5000/0...500 Ah/0.1 Ah |
|
| 5 | 0 | Name: BSH_NominalCapacity Function: set rated capacity |
File type: 08_BSH_NominalCapacity Value/range/increment: 0...250/0...500 Ah/2 Ah |
|
| 6 | 0 | Name: BSH_Recalibrated Function: Flag for SOC valid |
File type: 01_BSH_Recalibrated Value/name/function: 0/Not_Recalibrated/nicht neu kalibriert 1/Recalibrated/neu kalibriert |
|
| 03DH | 1 | 0 | Name: SlaveRespB0 | Value/function: 5/DIAGNOSTIC ADDRESS 'BSH' (5h) |
| 2 | 0 | Name: SlaveRespB1 | - | |
| 3 | 0 | Name: SlaveRespB2 | - | |
| 4 | 0 | Name: SlaveRespB3 | - | |
| 5 | 0 | Name: SlaveRespB4 | - | |
| 6 | 0 | Name: SlaveRespB5 | - | |
| 7 | 0 | Name: SlaveRespB6 | - | |
| 8 | 0 | Name: SlaveRespB7 | - | |