Plc Group 8 Signal List, PSM Function - GF54.21-D-3128TSA
Model 907
with code ED5 (Parameterisable special module)
Signal identification number = Signal ID.
SIGNAL LIST FOR PROGRAMMABLE LOGIC CONTROLLER (PLC) GROUP 8, PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value |
|---|---|---|---|---|
| Out_G8_HB | 0x1177 | PLC Group 8 hysteresis block: Exit not inverted | Bit | 0 |
| Out_G8_HB_inv | 0x1178 | PLC Group 8 hysteresis block: Exit inverted | Bit | 1 |
| Out_G8_SS1_A | 0x1179 | PLC group 8, threshold switch 1: Output A | Bit | 0 |
| Out_G8_SS1_B | 0x117A | PLC group 8, threshold switch 1: Output B | Bit | 0 |
| Out_G8_SS1_C | 0x117B | PLC group 8, threshold switch 1: Output C | Bit | 0 |
| Out_G8_SS1_D | 0x117C | PLC group 8, threshold switch 1: Output D | Bit | 0 |
| Out_G8_SS2_A | 0x117D | PLC Group 8 threshold switch 2: Exit A | Bit | 0 |
| Out_G8_SS2_B | 0x117E | PLC Group 8 threshold switch 2: Exit B | Bit | 0 |
| Out_G8_SS2_C | 0x117F | PLC Group 8 threshold switch 2: Exit C | Bit | 0 |
| Out_G8_SS2_D | 0x1180 | PLC Group 8 threshold switch 2: Exit D | Bit | 0 |
| Out_G8_LB1 | 0x1181 | PLC group 8, logic block 1: Output not inverted | Bit | 0 |
| Out_G8_LB1_inv | 0x1182 | PLC group 8, logic block 1: Output inverted | Bit | 1 |
| Out_G8_LB2 | 0x1183 | PLC group 8, logic block 2: Output not inverted | Bit | 0 |
| Out_G8_LB2_inv | 0x1184 | PLC group 8, logic block 2: Output inverted | Bit | 1 |
| Out_G8_LB3 | 0x1185 | PLC group 8, logic block 3: Output not inverted | Bit | 0 |
| Out_G8_LB3_inv | 0x1186 | PLC group 8, logic block 3: Output inverted | Bit | 1 |
| Out_G8_LB4 | 0x1187 | PLC group 8, logic block 4: Output not inverted | Bit | 0 |
| Out_G8_LB4_inv | 0x1188 | PLC group 8 logic block 4: Output inverted | Bit | 1 |
| Out_G8_LB5 | 0x1189 | PLC group 8, logic block 5: Output not inverted | Bit | 0 |
| Out_G8_LB5_inv | 0x118A | PLC group 8 logic block 5: Output inverted | Bit | 1 |
| Out_G8_LB6 | 0x118B | PLC group 8, logic block 6: Output not inverted | Bit | 0 |
| Out_G8_LB6_inv | 0x118C | PLC group 8, logic block 6: Output inverted | Bit | 1 |
| Out_G8_LB7 | 0x118D | SPS Group 8, logic block 7: Exit not inverted | Bit | 0 |
| Out_G8_LB7_inv | 0x118E | PLC Group 8, logic block 7: Exit inverted | Bit | 1 |
| Out_G8_LB8 | 0x118F | SPS Group 8, logic block 8: Exit not inverted | Bit | 0 |
| Out_G8_LB8_inv | 0x1190 | PLC Group 8, logic block 8: Exit inverted | Bit | 1 |
| Out_G8_FF1 | 0x3064 | PLC group 8, flip flop 1: Output not inverted | Data word (Word) | 0 |
| Out_G8_FF1_inv | 0x1191 | PLC group 8, flip flop 1: Output inverted | Bit | 1 |
| Out_G8_FF2 | 0x3065 | PLC group 8 flip-flop 2: Output not inverted | Data word (Word) | 0 |
| Out_G8_FF2_inv | 0x1192 | PLC group 8 flip-flop 2: Output inverted | Bit | 1 |
| Out_G8_TB | 0x1193 | PLC Group 8 timer block: Exit not inverted | Bit | 0 |
| Out_G8_TB_inv | 0x1194 | PLC Group 8 timer block: Exit inverted | Bit | 1 |
| Out_G8_CNT | 0x3066 | PLC group 8, counter | Data word (Word) | 0 |
| Out_G8_WT1 | 0x3067 | PLC group 8, value table 1 | Data word (Word) | 0 |
| Out_G8_K1_value | 0x3068 | PLC group 8, constant 1 | Data word (Word) | 0 |
| Out_G8_K2_value | 0x3069 | PLC group 8, constant 2 | Data word (Word) | 0 |
| Out_G8_K3_value | 0 x 306A | PLC group 8, constant 3 | Data word (Word) | 0 |
| Out_G8_K4_value | 0 x 306B | PLC group 8, constant 4 | Data word (Word) | 0 |
| Out_G8_K5_value | 0 x 306C | PLC group 8, constant 5 | Data word (Word) | 0 |
| Overview of system components for parameterizable special module (PSM) | GF54.21-D-9998TSA |