Plc Group 1 Signal List, PSM Function - GF54.21-D-3118TSA
Model 907
with code ED5 (Parameterisable special module)
Signal identification number = Signal ID.
PROGRAMMABLE LOGIC CONTROLLER (PLC) GROUP 1 SIGNAL LIST, PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value |
|---|---|---|---|---|
| Out_G1_HB | 0x510A | PLC group 1 hysteresis block: Output not inverted | Bit | 0 |
| Out G1 HB inv | 0x610A | PLC group 1 hysteresis block: Output inverted | Bit | 1 |
| Out_G1_SS1_A | 0x710A | PLC group 1 threshold switch 1: Output A | Bit | 0 |
| Out_G1_SS1_B | 0x810A | PLC group 1 threshold switch 1: Output B | Bit | 0 |
| Out_G1_SS1_C | 0x910A | PLC group 1 threshold switch 1: Output C | Bit | 0 |
| Out_G1_SS1_D | 0x10AA | PLC group 1 threshold switch 1: Output D | Bit | 0 |
| Out_G1_SS2_A | 0x10AB | PLC group 1 threshold switch 2: Output A | Bit | 0 |
| Out_G1_SS2_B | 0x10AC | PLC group 1 threshold switch 2: Output B | Bit | 0 |
| Out_G1_SS2_C | 0x10AD | PLC group 1 threshold switch 2: Output C | Bit | 0 |
| Out_G1_SS2_D | 0x10AE | PLC group 1 threshold switch 2: Output D | Bit | 0 |
| Out_G1_LB1 | 0x10AF | PLC group 1 logic block 1: Output not inverted | Bit | 0 |
| Out_G1_LB1_inv | 0x010B | PLC group 1 logic block 1: Output inverted | Bit | 1 |
| Out_G1_LB2 | 0x110B | PLC group 1 logic block 2: Output not inverted | Bit | 0 |
| Out_G1_LB2_inv | 0x210B | PLC group 1 logic block 2: Output inverted | Bit | 1 |
| Out_G1_LB3 | 0x310B | PLC group 1 logic block 3: Output not inverted | Bit | 0 |
| Out_G1_LB3_inv | 0x410B | PLC group 1 logic block 3: Output inverted | Bit | 1 |
| Out_G1_LB4 | 0x510B | PLC group 1 logic block 4: Output not inverted | Bit | 0 |
| Out_G1_LB4_inv | 0x610B | PLC group 1 logic block 4: Output inverted | Bit | 1 |
| Out_G1_LB5 | 0x710B | PLC group 1 logic block 5: Output not inverted | Bit | 0 |
| Out_G1_LB5_inv | 0x810B | PLC group 1 logic block 5: Output inverted | Bit | 1 |
| Out_G1_LB6 | 0x910B | PLC group 1 logic block 6: Output not inverted | Bit | 0 |
| Out_G1_LB6_inv | 0x10BA | PLC group 1 logic block 6: Output inverted | Bit | 1 |
| Out_G1_LB7 | 0x10BB | PLC group 1 logic block 7: Output not inverted | Bit | 0 |
| Out_G1_LB7_inv | 0x10BC | PLC group 1 logic block 7: Output inverted | Bit | 1 |
| Out_G1_LB8 | 0x10BD | PLC group 1 logic block 8: Output not inverted | Bit | 0 |
| Out_G1_LB8_inv | 0x10BE | PLC group 1 logic block 8: Output inverted | Bit | 1 |
| Out_G1_FF1 | 0x3025 | PLC group 1 flip flop 1: Output not inverted | Data word (Word) | 0 |
| Out_G1_FF1_inv | 0x10BF | PLC group 1 flip flop 1: Output inverted | Bit | 1 |
| Out_G1_FF2 | 0x3026 | PLC group 1 flip flop 2: Output not inverted | Bit | 0 |
| Out_G1_FF2_inv | 0x010C | PLC group 1 flip flop 2: Output inverted | Bit | 1 |
| Out_G1_TB | 0x110C | PLC group 1 timer block: Output not inverted | Bit | 0 |
| Out_G1_TB_inv | 0x210C | PLC group 1 timer block: Output inverted | Bit | 1 |
| Out_G1_CNT | 0x3027 | PLC group 1 counter | Data word (Word) | 0 |
| Out_G1_WT1 | 0x3028 | PLC group 1 value table 1 | Data word (Word) | 0 |
| Out_G1_K1_value | 0x3029 | PLC group 1 constant 1 | Data word (Word) | 0 |
| Out_G1_K2_value | 0 x 302A | PLC group 1 constants 2 | Data word (Word) | 0 |
| Out_G1_K3_value | 0 x 302B | PLC group 1 constants 3 | Data word (Word) | 0 |
| Out_G1_K4_value | 0 x 302C | PLC group 1 constants 4 | Data word (Word) | 0 |
| Out_G1_K5_value | 0 x 302D | PLC group 1 constants 5 | Data word (Word) | 0 |
| Overview of system components for parameterizable special module (PSM) | GF54.21-D-9998TSA |