Home >> Mercedes Benz >> 2021 >> Sprinter 1500 Van Passenger >> Repair and Diagnosis >> Accessories & Equipment >> Wiper/Washer Systems >> Electrical System, Equipment & Instructions - Description & Operation, Location, Gen Info & Basic Knowledge >> Basic Knowledge >> PARAMETERIZABLE Special Module (PSM) Control Unit Connector Assignment - GF54.21-D-0002-04TSB

PARAMETERIZABLE Special Module (PSM) Control Unit Connector Assignment - GF54.21-D-0002-04TSB

Model 907 

with code ED5 (Parameterisable special module) 

An electric step, right or left 

Pin assignment for an electric step, right or left 

G13792252
PLUG 1

Pin no. Use Assignment Function
1 Tml. 30_2 Tml. 30 Voltage supply
2 Multifunction output 02 10 A, tml. 30_2 -
3 Multifunction output 05 5 A, tml. 30_2 -
4 Tml. 30_2 Tml. 30 Voltage supply
5 Multifunction output 01 5 A, tml. 30_2 -
6 Multifunction output 18 5 A, tml. 30_2 -
7 Multifunction output 04 10 A, tml. 30_1 Right sliding door electric step or left sliding door electric step
8 Not used Not used -
9 Ground return conductor (maximum 7.5 A) Tml. 31 -
10 Tml. 30_1 Tml. 30 Voltage supply
11 Multifunction output 03 5 A, bridge, tml. 30_1 -
12 Multifunction output 19 5 A, tml. 30_1 -
13 Tml. 30_1 Tml. 30 -
14 Multifunction output 20 5 A, bridge, tml. 30_1 Right sliding door electric step or left sliding door electric step
15 Tml. 31 Tml. 31 Ground connection
CONNECTOR 2

Pin no. Use Assignment Function
1 Multifunction output 11 0.5 A Low Side -
2 Multifunction output 14 0.5 A Low Side -
3 Multifunction output 15 0.5 A Low Side, travel distance signal (not configurable) -
4 Multifunction output 08 0.5 A High Side KL30_1 -
5 Multifunction output 09 0.5 A High Side KL30_1 -
6 Multifunction output 10 0.5 A High Side KL30_1 -
7 Multifunction input 05 Low Side Right sliding door electric step or left sliding door electric step
8 Multifunction input 06 Analog Right sliding door electric step or left sliding door electric step
9 Multifunction input 01 Analog -
10 Multifunction input 10 Analog Right sliding door electric step or left sliding door electric step
11 Multifunction input 07 Analog -
12 Not used Not used -
13 Ground return conductor 1 (maximum 1 A) Tml. 31 -
14 PSM CAN shielding (ground connection) Shielding Shielding
15 Ground return conductor 2 (maximum 1 A) Tml. 31 -
16 Body manufacturer CAN (CAN ABH) (CAN ABH_H) -
17 Multifunction output 13 1 A Low Side -
18 Multifunction output 17 1 A Low Side -
19 Multifunction output 12 0.5 A Low Side Right sliding door electric step or left sliding door electric step
20 Multifunction output 07 1 A High-Side KL30_1 -
21 Multifunction output 06 1 A High-Side KL30_1 -
22 Multifunction output 16 0.5 A High Side KL30_1 -
23 Multifunction input 04 High Side -
24 Multifunction input 08 Analog Right sliding door electric step or left sliding door electric step
25 Multifunction input 09 Analog -
26 Multifunction input 02 High Side -
27 Multifunction input 03 High Side -
28 Interior CAN (CAN B) (CAN B_L) -
29 Interior CAN (CAN B) (CAN B_H) -
30 Peripheral device CAN (CAN AE) (CAN AE_L) -
31 Peripheral device CAN (CAN AE) (CAN AE_H) -
32 Body manufacturer CAN (CAN ABH) (CAN ABH_L) -