Remove Contacts From Standard Power Timer Coupling - Ar00.19-P-0120-10A
Unfasten secondary release on version with tab
- Using a suitable tool, at the line side unlock the lugs (1) on lock tab.
- Open the tab.
Unfasten secondary release on version with spring (shown on Junior Power Timer, Standard Power Timer coupling)
- Insert a suitable tool between spring (1) and housing and then press spring (1) out.
Unfasten secondary release on version with slide
- Using a suitable tool, push the slide valve out of the last detent in direction shown by arrow.
Press carefully with the tool so that the gasket at the slide valve is not damaged.
Unpin female contacts from coupling
- Insert blade holder with
clamping pliers with
JPT/SPT blade or
MCP 2.8/Fl. 2.8/JPT/SPT blade from the front through the openings in contact cavity of coupling (1).
This step compresses the spring shackles (2) on the female contact.
- A slight tug on the corresponding cable will remove the female contact (1) from the coupling.