Remove Contacts From Fin Sensor Contact Coupling - Ar00.19-P-0120-12A
Unfasten secondary release on version with spring (shown on laminated sensor contact, Junior Power Timer coupling)
- Insert a suitable tool between the spring and the housing.
- Press out the spring.
Unfasten secondary release on version with slide (shown on laminated sensor contact, Junior Power Timer coupling)
- Push (1) slider out of locked position in direction of arrow.
Unfasten secondary release on version with pin
- Using a suitable tool, push pin out of last detent in direction shown by arrow.
Unpin female contacts from coupling
- Insert blade holder with
clamping pliers and
LSK 8 blade from front side though openings at contact cavity of coupling (1).
This step compresses the spring shackles (2) on the female contact.
- A slight tug on the corresponding cable will remove the female contact (1) from the coupling.