Variant Coding Signal List, PSM Function - GF54.21-D-3131TSA
Model 907
with code ED5 (Parameterisable special module)
Signal identification number = Signal ID.
VARIANT CODING SIGNAL LIST, PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value |
|---|---|---|---|---|
| VC_Audio_Mute | 0x1069 | Coding for mute function | Bit | 0 |
| VC_DZ_Off_ZV_Zu | 0 x106A | Coding for roof sign OFF, central locking activated. | Bit | 0 |
| VC_DZ_not_load_monitor | 0 x106B | Coding for roof sign load monitor | Bit | 0 |
| VC_DZ_PWM_Off | 0 x106C | Variant coding for pulse width modulated signal for roof sign: no → 0, yes → 1. |
Bit | 0 |
| VC_DZ_via_MFL | 0 x106D | Variant coding for roof sign operation via multifunction steering wheel buttons: no → 0, yes → 1. |
Bit | 0 |
| VC_DZ_as_peripheral_supply | 0 x106E | Variant coding: the roof sign lamp is switched off at the same time as the peripheral devices. | Bit | 0 |
| VC_REmergency_call_Static | 0 x106F | Radio help call coding static | Bit | 0 |
| VC_PAS_recirculated_air | 0x1070 | Air recirculation mode coding panic alarm system | Bit | 0 |
| VC_SAlarm_DZ | 0x1071 | Coding for roof sign silent alarm | Bit | 0 |
| VC_FAlarm_DZ | 0x1072 | Coding for roof sign full alarm | Bit | 0 |
| VC_VAlarm_Interior lights | 0x1073 | Interior illumination coding full alarm | Bit | 0 |