LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> Sprinter 1500 Van Cargo >> Repair and Diagnosis >> Body & Frame >> Body, Cab Control Systems >> ELECTRICAL SYSTEM, EQUIPMENT & INSTRUCTIONS - BASIC KNOWLEDGE (1 of 2) >> Basic Knowledge >> Signal List, Caravan Control Unit, Air Conditioning System, Function - GF54.21-D-5060TSA

Signal List, Caravan Control Unit, Air Conditioning System, Function - GF54.21-D-5060TSA

Model 907 

with code JA3 (Intelligent body control.) 

SIGNAL LIST FOR AIR CONDITIONING SYSTEM LIN CONNECTIONS

Signal ID Type/number Signal name Function File type Value Name/range Setting/Step width
  Byte Bit            
008h 1 0 AACDometic_TempMode_Rq "iFeel" function 01_AACDometic_TempMode 0 Enable "iFeel" function activated.
            1 Disable "iFeel" function deactivated.
  1 1 AACDometic ModeA_Rq Operating mode A 01 AACDometic ModeA - - -
  1 2 AACDometic_FanMode_Rq Ventilation mode 01 AACDometic FanMode 0 AUTO Automatic mode
            1 Manual Manual mode
  1 3 AACDometic_SleepMode_Rq Sleep function 01_AACDometic_SleepMode 0 Disable Sleep function deactivated
            1 Enable Sleep function activated
  1 4 AACDometic_TimerOffMode_Rq Timer flag OFF 01_AACDometic_TimerOffMode 0 Disable Timer OFF deactivated
            1 Enable Timer OFF activated
  1 5 AACDometic_TimerOnMode_Rq Timer flag ON 01_AACDometic_TimerOnMode 0 Disable Timer ON deactivated
            1 Enable Timer ON activated
  1 6 AACDometic_Light_Rq Status of lighting system 01_AACDometic_Light 0 OFF Lighting system OFF
            1 On Lighting system ON
  1 7 AACDometic_Power_Rq A/C status 01_AACDometic_Power 0   A/C OFF
            1   Air conditioning ON
008h 2 0 AACDometic_Mode_B_Rq Operating mode B The value of the function is a combination of operating mode A and B. 02 AACDometic ModeB 0 DRY_AUTO A = 0,
value = "DRY"
A = 1,
value = "AUTO"
            1 RES_COOL A = 0,
value = "RESERVED"
A = 1,
value = "COOL"
            2 ACTIVE_VENT_HEAT A = 0,
value = "ACTIVE VENTILATION"
A = 1,
value = "HEAT"
            3 RES_FAN A = 0,
value = "RESERVE D"
A = 1,
value = "FAN"
  2 2 AACDometic_Speed_Rq Fan speed 02_AACDometic_Speed 0 Speed1 Stage 1
            1 Speed2 Stage 2
            2 Speed3 Stage 3
            3 Speed4 Stage 4
  2 4 AACDometic_Temp_Rq Specified temperature 04_AACDometic_Temp 0...15 -16...-1-C 1 °C
008h 3 0 AACDometic_OnTimerMSBits_Rq Minutes ON, left 08_AACDometic_OnTimerMSBits 0...255 0...2550 min 10 min
  4 0 AACDometic_OffTimerMSBits_Rq Minutes OFF, left 08_AACDometic_OffTimerMSBits 0...255 0...2550 min 10 min
  5 0 AACDometic_TimerMinLSBits_Rq Remaining timer time within 10-minute cycle. 04_AACDometic_TimerMinLSBits - - -
  5 4 AACDometic_IFeelTemp_Rq Outside temperature for "iFeel" function 04_AACDometic_IFeelTemp 0...15 -16...-1 °C 1 °C
  6 0 AACDometic_EconomyOn_Rq Economy function status 01_AACDometic_EconomyOn 0 Disable Economy mode deactivated
            1 Enable Economy mode activated
  6 1 AACDometic_InverterOn_Rq External inverter function status 01_AACDometic_Inverter On 0 Disable External inverter deactivated
            1 Enable External inverter activated
  6 2 AACDometic_UVLamp_Rq Function status of UV lamp 01_AACDometic_UVLamp 0 Disable UV lamp deactivated
            1 Enable UV lamp activated
  6 3 AACDometic_DimmerLevel_Rq Lighting system level 05_AACDometic_Dimmer Level 0...31 5...160 % 5 %
  7 0 AACDometic_Rsrv2 Reserved for future use. Rsrv08 - - -
  8 0 AACDometic_RemoteCtrlDis Deactivate remote control. 01_AACDometic_RemoteCtrlDis 0 Enable ACTIVATED
            1 Disable is deactivated
Signal ID Type/number Signal name Function File type Value Name/range Setting/Step width
  Byte Bit            
017h 1 0 AACDometic_TempMode_Rs "iFeel" function 01_AACDometic_TempMode 0 Enable "iFeel" function activated.
            1 Disable "iFeel" function deactivated.
  1 1 AACDometic+Mode_A_Rs Operating mode A 01 AACDometic Mode_A - - -
  1 2 AACDometic_FanMode_Rs Ventilation mode 01 AACDometic FanMode 0 AUTO Automatic mode
            1 Manual Manual mode
  1 3 AACDometic_SleepMode_Rs Sleep function 01_AACDometic_SleepMode 0 Disable Sleep function deactivated
            1 Enable Sleep function activated
  1 4 AACDometic_TimerOffMode_Rs Timer flag OFF 01_AACDometic_TimerOffMode 0 Disable Timer OFF deactivated
            1 Enable Timer OFF activated
  1 5 AACDometic_TimerOnMode_Rs Timer flag ON 01_AACDometic_TimerOnMode 0 Disable Timer ON deactivated
            1 Enable Timer ON activated
  1 6 AACDometic_Light_Rs Lighting system 01_AACDometic_Light 0 OFF Lighting system OFF
            1 On Lighting system ON
  1 7 AACDometic_Power_Rs A/C status 01_AACDometic_Power 0 OFF A/C OFF
            1 On Air conditioning ON
017h 2 0 AACDometic_Mode_B_Rs Operating mode B The value of the function is a combination of operating mode A and B. 02_AACDometic_Mode_B 0 DRY_AUTO A = 0,
value = "DRY"
A = 1,
value = "AUTO"
            1 RES_COOL A = 0,
value = "RESERVED"
A = 1,
value = "COOL"
            2 ACTIVE_VENT_HEAT A = 0,
value = "ACTIVE VENTILATION"
A = 1,
value = "HEAT"
            3 RES_FAN A = 0,
value = "RESERVED"
A = 1,
value = "FAN"
  2 2 AACDometic_Speed_Rs Fan speed 02_AACDometic_Speed 0 Speed1 Stage 1
            1 Speed2 Stage 2
            2 Speed3 Stage 3
            3 Speed4 Stage 4
  2 4 AACDometic_Temp_Rs Specified temperature 04_AACDometic_Temp 0...15 -16...-1 °C 1 °C
017h 3 0 AACDometic_OnTimerMSBits_Rs Minutes ON, left 08_AACDometic_OnTimerMSBits 0...255 0...2550 min 10 min
  4 0 AACDometic_OffTimerMSBits_Rs Minutes OFF, left 08_AACDometic_OffTimerMSBits 0...255 0...2550 min 10 min
  5 0 AACDometic_TimerMinLSBits_Rs Remaining timer time within 10-minute cycle. 04_AACDometic_TimerMinLSBits      
  5 4 AACDometic_IFeelTemp_Rs Outside temperature for "iFeel" function 04_AACDometic_IFeelTemp 0...15 -16...-1 °C 1 °C
  6 0 AACDometic_EconomyOn_Rs Economy function status 01_AACDometic_EconomyOn 0 Disable Economy mode deactivated
            1 Enable Economy mode activated
  6 1 AACDometic_InverterOn_Rs External inverter function status 01_AACDometic_InverterOn 0 Disable External inverter deactivated
            1 Enable External inverter activated
  6 2 AACDometic_UVLamp_Rs Function status of UV lamp 01_AACDometic_UVLamp 0 Disable UV lamp deactivated
            1 Enable UV lamp activated
  6 3 AACDometic_DimmerLevel_Rs Lighting system level 05_AACDometic_DimmerLevel 0...31 5...160 % 5 %
017h 7 0 - - - - -
  7 1 AACDometic_CompRun Compressor status 01_AACDometic_CompRun 0 OFF Compressor OFF
            1 On Compressor ON
  7 2 AACDometic_UVLampOn Status of UV lamp 01_AACDometic_UVLampOn 0 OFF UV lamp OFF
            1 On UV lamp ON
  7 3 AACDometic_IntTemp Vehicle interior temperature 05_AACDometic_IntTemp - - -
  8 0 AACDometic_LocalChange Status changed by external actuation 01_AACDometic_LocalChange 1 Sync_Request Synchronization request
  8 1 AACDometic_NoMain Line failure 01_AACDometic_NoMain 1 Fail Line failed
  8 2 AACDometic_Error Temperature sensor fault 01_AACDometic_Error 0 No_Error No fault
            1 ERROR Fault
  8 3 AACDometic_TimerOnReq Air conditioning system ON due to timeout of timer ON 01_AACDometic_TimerOnReq 0 Not_Complete Timer ON not ready
1 Complete Timer ON ready
  8 4 AACDometic_Timer OffReq Air conditioning system OFF due to timeout of timer OFF 01 AACDometic TimerO ffReq 0 Not_Complete Timer OFF not ready
            1 Complete Timer OFF ready
  8 5 AACDometic_RemoteOn Air conditioning system ON due to remote input request 01_AACDometic_RemoteOn 0 Disable Remote control input deactivated.
            1 Enable Remote control input activated.
  8 6 AACDometic_NotInit Card not initialized 01_AACDometic_NotInit 0 Init INITIALIZED
            1 NotInit NOT INITIALIZED
  8 7 RsErr_AACDometic Fault on CI bus 01_AACDometic_CIError 0 No_Error No fault
            1 ERROR Fault
Signal ID Type/number Signal name Function File type Value Name/range Setting/Step width
  Byte Bit            
03DH 1 0 SlaveRespB0 - - 3 - Address "AACDometic" (3h)
  2 0 SlaveRespB1          
  3 0 SlaveRespB2          
  4 0 SlaveRespB3          
  5 0 SlaveRespB4          
  6 0 SlaveRespB5          
  7 0 SlaveRespB6          
  8 0 SlaveRespB7          
Signal ID Type/number Signal name Function File type Value Name/range Setting/Step width
  Byte Bit            
008h 8 1 AACDometic_RemoteOnDisable Remote control input deactivated. 01_AACDometic_RemoteOnDisable 0 Enable ACTIVATED
            1 Disable is deactivated
  8 2 AACDometic_SyncFrame CI master at air conditioning system synchronized 01_AACDometic_SyncFrame 1 Master_Synchro CI master synchronization
  8 3 AACDometic_TimerUpdate Timer update 01_AACDometic_TimerUpdate 1 UpdateTimer Timer updated
  8 4 AACDometic_SetInverterOff Deactivate output for external inverter 01_AACDometic SetInverterOff 0 ForceON Switched on
            1 ForceOFF Switched off
  8 5 AACDometic_SetInverterOn Release enable for external inverter. 01_AACDometic_SetInverterOn 0 ForceOFF Switched off
            1 ForceON Switched on
  8 6 AACDometic_Rsrv1 Reserved for future use. Rsrv02 - - -