Plc Group 9 Signal List, PSM Function - GF54.21-D-3129TSA
Model 907
with code ED5 (Parameterisable special module)
Signal identification number = Signal ID.
SIGNAL LIST OF PROGRAMMABLE LOGIC CONTROLLER (PLC) GROUP 9 PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value |
|---|---|---|---|---|
| Out_G9_HB | 0x1195 | PLC group 9 hysteresis block: Output not inverted | Bit | 0 |
| Out_G9_HB_inv | 0x1196 | PLC group 9 hysteresis block: Output inverted | Bit | 1 |
| Out_G9_SS1_A | 0x1197 | PLC group 9 threshold switch 1: Output A | Bit | 0 |
| Out_G9_SS1_B | 0x1198 | PLC group 9 threshold switch 1: Output B | Bit | 0 |
| Out_G9_SS1_C | 0x1199 | PLC group 9 threshold switch 1: Output C | Bit | 0 |
| Out_G9_SS1_D | 0x119A | PLC group 9 threshold switch 1: Output D | Bit | 0 |
| Out_G9_SS2_A | 0x119B | PLC group 9 threshold switch 2: Output A | Bit | 0 |
| Out_G9_SS2_B | 0x119C | PLC group 9 threshold switch 2: Output B | Bit | 0 |
| Out_G9_SS2_C | 0x119D | PLC group 9 threshold switch 2: Output C | Bit | 0 |
| Out_G9_SS2_D | 0x119E | PLC group 9 threshold switch 2: Output D | Bit | 0 |
| Out_G9_LB1 | 0x119F | PLC group 9 logic block 1: Output not inverted | Bit | 0 |
| Out_G9_LB1_inv | 0x011A | PLC group 9 logic block 1: Output inverted | Bit | 1 |
| Out_G9_LB2 | 0x111A | PLC group 9 logic block 2: Output not inverted | Bit | 0 |
| Out_G9_LB2_inv | 0x211A | PLC group 9 logic block 2: Output inverted | Bit | 1 |
| Out_G9_LB3 | 0x311A | PLC group 9 logic block 3: Output not inverted | Bit | 0 |
| Out_G9_LB3_inv | 0x411A | PLC group 9 logic block 3: Output inverted | Bit | 1 |
| Out_G9_LB4 | 0x511A | PLC group 9 logic block 4: Output not inverted | Bit | 0 |
| Out_G9_LB4_inv | 0x611A | PLC group 9 logic block 4: Output inverted | Bit | 1 |
| Out_G9_LB5 | 0x711A | PLC group 9 logic block 5: Output not inverted | Bit | 0 |
| Out_G9_LB5_inv | 0x811A | PLC group 9 logic block 5: Output inverted | Bit | 1 |
| Out_G9_LB6 | 0x911A | PLC group 9 logic block 6: Output not inverted | Bit | 0 |
| Out_G9_LB6_inv | 0x11AA | PLC group 9 logic block 6: Output inverted | Bit | 1 |
| Out_G9_LB7 | 0x11AB | PLC group 9 logic block 7: Output not inverted | Bit | 0 |
| Out_G9_LB7_inv | 0x11AC | PLC group 9 logic block 7: Output inverted | Bit | 1 |
| Out_G9_LB8 | 0x11AD | PLC group 9 logic block 8: Output not inverted | Bit | 0 |
| Out_G9_LB8_inv | 0x11AE | PLC group 9 logic block 8: Output inverted | Bit | 1 |
| Out_G9_FF1 | 0 x 306D | PLC group 9 flip-flop 1: Output not inverted | Data word (Word) | 0 |
| Out_G9_FF1_inv | 0x11AF | PLC group 9 flip-flop 1: Output inverted | Bit | 1 |
| Out_G9_FF2 | 0 x 306E | PLC group 9 flip flop 2: Output not inverted | Data word (Word) | 0 |
| Out_G9_FF2_inv | 0x011B | PLC group 9 flip flop 2: Output inverted | Bit | 1 |
| Out_G9_TB | 0x111B | PLC group 9 timer block: Output not inverted | Bit | 0 |
| Out_G9_TB_inv | 0x211B | PLC group 9 timer block: Output inverted | Bit | 1 |
| Out_G9_CNT | 0 x 306F | PLC group 9 counter | Data word (Word) | 0 |
| Out_G9_WT1 | 0x3070 | PLC group 9 value table 1 | Data word (Word) | 0 |
| Out_G9_K1_value | 0x3071 | PLC group 9 constant 1 | Data word (Word) | 0 |
| Out_G9_K2_value | 0x3072 | PLC group 9 constant 2 | Data word (Word) | 0 |
| Out_G9_K3_value | 0x3073 | PLC group 9 constant 3 | Data word (Word) | 0 |
| Out_G9_K4_value | 0x3074 | PLC group 9 constant 4 | Data word (Word) | 0 |
| Out_G9_K5_value | 0x3075 | PLC group 9 constant 5 | Data word (Word) | 0 |
| Overview of system components for parameterizable special module (PSM) | GF54.21-D-9998TSA |