LEMON Manuals: Even more car manuals for everyone
Home >> Mercedes Benz >> 2021 >> Sprinter 1500 Van Cargo >> Repair and Diagnosis >> Accessories & Equipment >> Wiper/Washer Systems >> Electrical System, Equipment & Instructions - Description & Operation, Location, Gen Info & Basic Knowledge >> Basic Knowledge >> Plc Group 12 Signal List, PSM Function - GF54.21-D-3121TSA

Plc Group 12 Signal List, PSM Function - GF54.21-D-3121TSA

Model 907 

with code ED5 (Parameterisable special module) 

IMPORTANT Signal identification number = Signal ID.

SIGNAL LIST OF PROGRAMMABLE LOGIC CONTROLLER (PLC) GROUP 12 PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION

Signal name Signal ID Description Signal type Default value
Out_G12_HB 0x11EF PLC group 12 hysteresis block: Output not inverted Bit 0
Out_G12_HB_inv 0x011F PLC group 12 hysteresis block: Output inverted Bit 1
Out_G12_SS1_A 0x111F PLC group 12 threshold switch 1: Output A Bit 0
Out_G12_SS1_B 0x211F PLC group 12 threshold switch 1: Output B Bit 0
Out_G12_SS1_C 0x311F PLC group 12 threshold switch 1: Output C Bit 0
Out_G12_SS1_D 0x411F PLC group 12 threshold switch 1: Output D Bit 0
Out_G12_SS2_A 0x511F PLC group 12 threshold switch 2: Output A Bit 0
Out_G12_SS2_B 0x611F PLC group 12 threshold switch 2: Output B Bit 0
Out_G12_SS2_C 0x711F PLC group 12 threshold switch 2: Output C Bit 0
Out_G12_SS2_D 0x811F PLC group 12 threshold switch 2: Output D Bit 0
Out_G12_LB1 0x911F PLC group 12 logic block 1: Output not inverted Bit 0
Out_G12_LB1_inv 0x11 FA PLC group 12 logic block 1: Output inverted Bit 1
Out_G12_LB2 0x11FB PLC group 12 logic block 2: Output not inverted Bit 0
Out_G12_LB2_inv 0x11 FC PLC group 12 logic block 2: Output inverted Bit 1
Out_G12_LB3 0x11FD PLC group 12 logic block 3: Output not inverted Bit 0
Out_G12_LB3_inv 0x11FE PLC group 12 logic block 3: Output inverted Bit 1
Out_G12_LB4 0x11FF PLC group 12 logic block 4: Output not inverted Bit 0
Out_G12_LB4_inv 0x1200 PLC group 12 logic block 4: Output inverted Bit 1
Out_G12_LB5 0x1201 PLC group 12 logic block 5: Output not inverted Bit 0
Out_G12_LB5_inv 0x1202 PLC group 12 logic block 5: Output inverted Bit 1
Out_G12_LB6 0x1203 PLC group 12 logic block 6: Output not inverted Bit 0
Out_G12_LB6_inv 0x1204 PLC group 12 logic block 6: Output inverted Bit 1
Out_G12_LB7 0x1205 PLC group 12 logic block 7: Output not inverted Bit 0
Out_G12_LB7_inv 0x1206 PLC group 12 logic block 7: Output inverted Bit 1
Out_G12_LB8 0x1207 PLC group 12 logic block 8: Output not inverted Bit 0
Out_G12_LB8_inv 0x1208 PLC group 12 logic block 8: Output inverted Bit 1
Out_G12_FF1 0x3088 PLC group 12 flip-flop 1: Output not inverted Data word (Word) 0
Out_G12_FF1_inv 0x1209 PLC group 12 flip-flop 1: Output inverted Bit 1
Out_G12_FF2 0x3089 PLC group 12 flip-flop 2: Output not inverted Data word (Word) 0
Out_G12_FF2_inv 0 x120A PLC group 12 flip-flop 2: Output inverted Bit 1
Out_G12_TB 0 x120B PLC group 12 timer block: Output not inverted Bit 0
Out_G12_TB_inv 0 x120C PLC group 12 timer block: Output inverted Bit 1
Out_G12_CNT 0 x 308A PLC group 12 counter Data word (Word) 0
Out_G12_WT1 0 x 308B PLC Group 12 Value table 1 Data word (Word) 0
Out_G12_K1_value 0 x 308C PLC group 12 constant 1 Data word (Word) 0
Out_G12_K2_value 0 x 308D PLC group 12 constant 2 Data word (Word) 0
Out_G12_K3_value 0 x 308E PLC group 12 constant 3 Data word (Word) 0
Out_G12_K4_value 0 x 308F PLC group 12 constant 4 Data word (Word) 0
Out_G12_K5_value 0x3090 PLC Group 12 Constant 5 Data word (Word) 0
Overview of system components for parameterizable special module (PSM) GF54.21-D-9998TSA