Plc Group 12 Signal List, PSM Function - GF54.21-D-3121TSA
Model 907
with code ED5 (Parameterisable special module)
Signal identification number = Signal ID.
SIGNAL LIST OF PROGRAMMABLE LOGIC CONTROLLER (PLC) GROUP 12 PARAMETERIZABLE SPECIAL MODULE (PSM) FUNCTION
| Signal name | Signal ID | Description | Signal type | Default value |
|---|---|---|---|---|
| Out_G12_HB | 0x11EF | PLC group 12 hysteresis block: Output not inverted | Bit | 0 |
| Out_G12_HB_inv | 0x011F | PLC group 12 hysteresis block: Output inverted | Bit | 1 |
| Out_G12_SS1_A | 0x111F | PLC group 12 threshold switch 1: Output A | Bit | 0 |
| Out_G12_SS1_B | 0x211F | PLC group 12 threshold switch 1: Output B | Bit | 0 |
| Out_G12_SS1_C | 0x311F | PLC group 12 threshold switch 1: Output C | Bit | 0 |
| Out_G12_SS1_D | 0x411F | PLC group 12 threshold switch 1: Output D | Bit | 0 |
| Out_G12_SS2_A | 0x511F | PLC group 12 threshold switch 2: Output A | Bit | 0 |
| Out_G12_SS2_B | 0x611F | PLC group 12 threshold switch 2: Output B | Bit | 0 |
| Out_G12_SS2_C | 0x711F | PLC group 12 threshold switch 2: Output C | Bit | 0 |
| Out_G12_SS2_D | 0x811F | PLC group 12 threshold switch 2: Output D | Bit | 0 |
| Out_G12_LB1 | 0x911F | PLC group 12 logic block 1: Output not inverted | Bit | 0 |
| Out_G12_LB1_inv | 0x11 FA | PLC group 12 logic block 1: Output inverted | Bit | 1 |
| Out_G12_LB2 | 0x11FB | PLC group 12 logic block 2: Output not inverted | Bit | 0 |
| Out_G12_LB2_inv | 0x11 FC | PLC group 12 logic block 2: Output inverted | Bit | 1 |
| Out_G12_LB3 | 0x11FD | PLC group 12 logic block 3: Output not inverted | Bit | 0 |
| Out_G12_LB3_inv | 0x11FE | PLC group 12 logic block 3: Output inverted | Bit | 1 |
| Out_G12_LB4 | 0x11FF | PLC group 12 logic block 4: Output not inverted | Bit | 0 |
| Out_G12_LB4_inv | 0x1200 | PLC group 12 logic block 4: Output inverted | Bit | 1 |
| Out_G12_LB5 | 0x1201 | PLC group 12 logic block 5: Output not inverted | Bit | 0 |
| Out_G12_LB5_inv | 0x1202 | PLC group 12 logic block 5: Output inverted | Bit | 1 |
| Out_G12_LB6 | 0x1203 | PLC group 12 logic block 6: Output not inverted | Bit | 0 |
| Out_G12_LB6_inv | 0x1204 | PLC group 12 logic block 6: Output inverted | Bit | 1 |
| Out_G12_LB7 | 0x1205 | PLC group 12 logic block 7: Output not inverted | Bit | 0 |
| Out_G12_LB7_inv | 0x1206 | PLC group 12 logic block 7: Output inverted | Bit | 1 |
| Out_G12_LB8 | 0x1207 | PLC group 12 logic block 8: Output not inverted | Bit | 0 |
| Out_G12_LB8_inv | 0x1208 | PLC group 12 logic block 8: Output inverted | Bit | 1 |
| Out_G12_FF1 | 0x3088 | PLC group 12 flip-flop 1: Output not inverted | Data word (Word) | 0 |
| Out_G12_FF1_inv | 0x1209 | PLC group 12 flip-flop 1: Output inverted | Bit | 1 |
| Out_G12_FF2 | 0x3089 | PLC group 12 flip-flop 2: Output not inverted | Data word (Word) | 0 |
| Out_G12_FF2_inv | 0 x120A | PLC group 12 flip-flop 2: Output inverted | Bit | 1 |
| Out_G12_TB | 0 x120B | PLC group 12 timer block: Output not inverted | Bit | 0 |
| Out_G12_TB_inv | 0 x120C | PLC group 12 timer block: Output inverted | Bit | 1 |
| Out_G12_CNT | 0 x 308A | PLC group 12 counter | Data word (Word) | 0 |
| Out_G12_WT1 | 0 x 308B | PLC Group 12 Value table 1 | Data word (Word) | 0 |
| Out_G12_K1_value | 0 x 308C | PLC group 12 constant 1 | Data word (Word) | 0 |
| Out_G12_K2_value | 0 x 308D | PLC group 12 constant 2 | Data word (Word) | 0 |
| Out_G12_K3_value | 0 x 308E | PLC group 12 constant 3 | Data word (Word) | 0 |
| Out_G12_K4_value | 0 x 308F | PLC group 12 constant 4 | Data word (Word) | 0 |
| Out_G12_K5_value | 0x3090 | PLC Group 12 Constant 5 | Data word (Word) | 0 |
| Overview of system components for parameterizable special module (PSM) | GF54.21-D-9998TSA |