Functional Scope Of Global Functions, PSM, Function - GF54.21-D-3009TSA
Model 907
with code ED5 (Parameterisable special module)
Parameterizable special module (PSM) display message
Activation (AND operation):
- Function input "MPM_MsgDisp_Rq" is active.
Function cancellation (OR operation):
- Input is withdrawn.
Active function:
- Signal in signal pool "Out_MPM_MPM_MsgDisp_Rq" is set ("1").
- If the internal request is canceled, the input has to be activated by pressing again.
Parameter:
- None
Switch on front interior illumination
Activation (AND operation):
- Function input "IL_F_On_Rq_MPM" is active.
Function cancellation (OR operation):
- The input is only canceled if the message time of at least 5 messages has expired.
- Timeout for 5 messages.
Active function:
- Signal in the signal pool "Out_MPM_IL_F_On_Rq_MPM" is set to active ("1") after 5 messages, even if the input was canceled in the meantime.
- If the internal request is canceled, the input has to be activated by pressing again.
If the "Out_MPM_IL_F_On_Rq_MPM" signal changes, the interior CAN (CAN B) is activated and it remains so for 5 to 7 s.
Parameter:
- None
NOTE:
- The receiver control unit evaluates the signal change from "0" to "1" and toggles the interior lights function.
- Only the switch-on edge is evaluated in the parameterizable special module (PSM) control unit (N26/15).
| Overview of system components for parameterizable special module (PSM) | GF54.21-D-9998TSA |